2.6.5.2 Measurement Type: Level and Volume (Loop Control = Volume)
Display
Fid Gain
xxx
44
Window
xxx
45
Conv Fct
xxxx
46
Scl Ofst
xxx
47
Neg Ampl
xxx
4
Pos Ampl
xxx
49
Signal
xxx
50
Compsate
(select)
51
7xKCorr
xxx
52
ElecTemp
xxx C
53
Max Temp
xxx C
54
Min Temp
xxx C
55
SZ Hyst
xx.x lu
56
57-642 ECLIPSE Model 705 Guided Wave Radar Transmitter for Hygienic Industries
Action
Superuser Password
Factory Parameter
Factory Parameter
Factory Parameter
Superuser Password
Superuser Password
Diagnostic Display
Superuser Parameter
Superuser Parameter
Diagnostic Display
Diagnostic Display
Diagnostic Display
Diagnostic Display
Comment
Calibration parameter
Calibration parameter
Diagnostic factory setting
Diagnostic factory setting
Indication of level signal amplitude
Select from None, Manual, Auto
Distance in mm from fiducial to user reference point
(7xK probe characteristic)
Present temperature in electronics compartment
(degrees Celsius)
Maximum electronics temperature recorded
Minimum electronics temperature recorded
Diagnostic factory setting
21