Fault Message - BONFIGLIOLI Active ACT 201-05 Brief Manual

230 v / 400 v 0.55 kw ... 30.0 kw
Table of Contents

Advertisement

9.3
The error code saved after a fault in parameter
troubleshooting and error diagnosis. The error code consists of the error group FXX
and the code number XX. The error message is to be acknowledged via the keys of
the control unit and digital input S1IND.
52
52

Fault message

Code
F00
00
No fault has occurred.
02
Frequency inverter overloaded (60 s), check load behavior
F01
03
Short-term overload (1 s), check motor and application parameters
00
Heat sink temperature too high, check cooling and fan.
F02
01
Temperature sensor defective or ambient temperature too low.
00
Inside temperature too high, check cooling and fan.
F03
01
Inside temperature too low, check electrical cabinet heating.
Motor temperature too high or sensor defective, check connection
00
S6IND.
F04
03
Phase failure, check motor and wiring.
00
Overloaded, check load situation and ramps.
03
Short circuit or earth fault, check motor and wiring.
F05
05
Asymmetric motor current, check motor and wiring.
06
Motor phase current too high, check motor and wiring.
07
Message from phase monitoring, check motor and wiring.
DC link voltage too high, check deceleration ramps and connected
00
brake resistor
01
DC link voltage too low, check mains voltage.
02
Power failure, check mains voltage and circuit
F07
03
Phase failure, check mains fuses and circuit.
04
Mains voltage UDC too high on switch-on, check voltage.
05
Mains voltage BC too high on switch-on, check voltage.
06
Mains voltage MC too high on switch-on, check voltage.
01
Electronics voltage too low, check control terminals.
F08
04
Electronics voltage too high, check wiring of control terminals.
00
Output frequency too high, check control signals and settings.
F11
Max. frequency achieved by control, check deceleration ramps and
01
connected brake resistor.
00
Earth fault on output, check motor and wiring.
F13
10
Minimum current monitoring, check motor and wiring.
01
Reference value signal on multifunctional input 1 faulty, check signal.
F14
07
Overcurrent on multifunctional input 1, check signal.
Error messages
Meaning
Overload
Heat sink
Inside temperature
Motor connection
Output current
DC link voltage
Electronics voltage
Output frequency
Motor connection
Control connection
Last Error
310 facilitates
06/05
06/05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents