Relay Output - BONFIGLIOLI Active ACT 201-05 Brief Manual

230 v / 400 v 0.55 kw ... 30.0 kw
Table of Contents

Advertisement

Ter.
Ter.
1)
5.6.1
By default, the freely programmable relay output is linked to the monitoring function
(factory setting). The logic link to various functions can be freely configured via the
software parameters. Connection of the relay output is not absolutely necessary for
the function of the frequency inverter.
1 ... 3
30
30
1
Voltage output 20 V, I
2
Ground / GND 20 V
3
Digital input S1IND, U
response time approx. 16ms (on), 10 µs (off)
4
Digital input EM-S2IND, U
response time approx. 16 ms
5
Digital input EM-S3IND, U
response time approx. 16 ms
6
Digital input S4IND, U
frequency signal: 0...30 V, 10 mA at 24 V, f
7
Digital input S5IND, U
frequency signal: 0...30 V, 10 mA at 24 V, f
1
Digital input S6IND, U
response time approx. 16 ms
2
Ground / GND 20 V
3
Digital output S1OUT, U=24 V, I
4
Multi-function output MFO1,
analog signal: U=24 V, I
digital signal: U=24 V, I
frequency signal: 0...24 V, I
5
Reference output 10 V, I
6
Multi-function input MFI1,
analog signal: resolution 12 Bit, 0...+10 V (Ri = 70 kΩ), 0...20 mA (Ri = 500 Ω),
digital signal: response time approx. 16 ms, U
PLC compatible
7
Ground / GND 10 V
The power supply at terminal X210A.1 may be loaded with a maximum current
of I
= 180 mA. The maximum current available is reduced by the digital
max
output S1OUT and multifunctional output MFO1.

Relay Output

X10
Ter.
Relay output, floating change-over contact, response time approx. 40 ms,
max. contact load, make contact 5 A / 240 V AC, 5 A (ohmic) / 24 V DC
max. contact load, break contact 3 A / 240 V AC, 1 A (ohmic) / 24 V DC
Control terminal X210A
Description
1)
=180 mA
max
=30 V, 10 mA at 24 V, PLC compatible,
max
=30 V, 10 mA at 24 V, PLC compatible,
max
=30 V, 10 mA at 24 V, PLC compatible,
max
= 30 V, 10 mA at 24 V, PLC compatible,
max
max
= 30 V, 10 mA at 24 V, PLC compatible,
max
max
Control terminal X210B
Description
=30 V, 10 mA at 24 V, PLC compatible,
max
=40 mA, overload and short-circuit proof
max
=40 mA, pulse-width modulated, f
max
=40 mA, overload and short-circuit proof,
max
=40 mA, f
=150 kHz
max
max
=4 mA
max
Relay Output
X10
1
2
S3OUT
3
Control terminal X10
Description
= 150 kHz
= 150 kHz
=116 Hz
PWM
= 30 V, 4 mA at 24 V,
max
Phoenix ZEC 1,5/3ST5,0
0.2 ... 1.5 mm
AWG 24 ... 16
0.2 ... 1.5 mm
AWG 24 ... 16
0.25 ... 1.5 mm
AWG 22 ... 16
0.25 ... 1.5 mm
AWG 22 ... 16
2
2
2
2
06/05
06/05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents