Rain Bird ESP-SMT Installation & Operation Manual page 8

Smart modular control system
Table of Contents

Advertisement

Custom Values
For more advanced users, the controller will allow the
user to overwrite the default values with a user selected
value further optimizing the irrigation schedule to
match specific site conditions.
Event Days Off
Allows you to select up to four specific dates in which
you want to block irrigation from occurring. This can be
useful if you have planned an event that will take place
in the yard on specific dates.
Short Circuit Test
Enable you to perform a electronic diagnostic test to
determine on a zone by zone basis if there is a "Short"
circuit or if the circuit is "Good".
Cold Weather Shutdown
All irrigation will be suspended to prevent potential
freeze damage to the irrigation components if the
measured temperature is below a user set level.
Rainfall Shutdown
Irrigation will be suspended if the measured rainfall
exceeds a user set threshold.
Individual Zone Shutdown
Each individual zone can be either set in an "active" or
"inactive" mode. This is ideal if repairs are necessary on
a zone and you want to continue irrigating the other
zones on the system.
ESP-SMT Smart Modular Control System
3
System Review
Allows the user to look at a log of irrigation and alarm
events by date or by zone. Additionally, the user can
view the next estimated scheduled irrigation cycle by
zone and review the current and past weather data.
Suspend Irrigation
Allows the user to suspend irrigation for a period of
time (1 minute to 14 days), at which time the system will
return to the AUTO mode.
Save & Restore Settings
Save your current program in memory, so that if the
program gets changed inadvertently, you can easily
retrieve the previously saved program.
Manually Water Combination of Zones
User can set a zone or any combination of zones to run
manually, each with it's own run time prior to returning
to the AUTO mode.
Manually Water all Zones (TEST)
All zones that are present in the available modules can
be set to run for the same period of time sequentially.
This is a time-saver in performing a system walkthrough
and/or when winterizing a system.
Fine Tune by Zone
Each zone's calculated run-time can easily be adjusted
from an increase of up to 30% to a decrease of 30%
without changing any of the other pre-set programming
information that was entered in the initial controller and
zone set-up.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents