Power supply
Specification
Lambda probe
Left injector
Right injector
Fuel pump relay
Left coil
Right coil
Idle regulator
Battery voltage
Starter diagnosis
Engine revolution sensor
Lambda heater
SPEED SENSOR
CAN line diagnosis
RAM memory
ROM memory
Microprocessor
Checksum EPROM

SETTINGS screen page

This screen page is used to adjust some control
unit parameters.
Specification
Throttle positioner autodetection
P SUPP - 190
Possible short circuit on the earth lead, battery or open circuit
or plausibility: recovery function hardly noticeable for customer.
Possible short circuit in the earth lead, battery or open circuit.
If both injectors do not work, the engine does not work
Possible short circuit in the earth lead, battery or open circuit.
If both injectors do not work, the engine does not work
Possible short circuit in the earth lead, battery or open circuit:
Possible short circuit in the earth lead, battery or open circuit.
If both coils do not work, the engine does not work.
Possible short circuit in the earth lead, battery or open circuit.
If both coils do not work, the engine does not work.
Possible short circuit in the earth lead, battery or open circuit:
recovery function noticeable for the customer due to no idle
Battery voltage detected is too low (7V) or too high (16V) for a
Possible short circuit in the earth lead, battery or open circuit.
Possible short circuit in the earth lead, battery or lambda probe
<span style="FONT-SIZE: 12pt; FONT-FAMILY: "Times New
Roman"; mso-fareast-font-family: "Times New Roman"; mso-
ansi-language: IT; mso-fareast-language: IT; mso-bidi-lan-
guage: AR-SA">Possible error on line CAN: short circuit or line
break or no signal or plausibility error detected.
Possible internal control unit error. Also check the control unit
supply and earth connections
Possible internal control unit error. Also check the control unit
supply and earth connections
Possible internal control unit error. Also check the control unit
supply and earth connections
Possible internal control unit error. Also check the control unit
supply and earth connections
ADJUSTMENTS
Allows the control unit to detect the closed throttle position: just
STELVIO 4V - 1200
Desc./Quantity
the engine does not start.
management
certain period
Possible open circuit.
heating circuit open.