Basler A202K Manual page 34

Hide thumbs Also See for A202K:
Table of Contents

Advertisement

Operation and Features
Case 1 - Exposure Start With Frame Valid High
Figure 3-6: ExSync, Programmable Mode - Exposure Start with Frame Valid High
If the ExSync signal rises while frame valid is high as shown in Figure 3-6:
• The actual start of exposure can be up to 25 µs later than the rise of the ExSync signal.
(This is commonly referred to as an exposure start jitter.)
• The actual length of the exposure time will be equal to the programmed exposure time plus
94.5 µs minus the jitter time.
As shown in Figure 3-6, FVAL must be low for at least 1 µs before the programmed
exposure time ends.
3-8
EXSYNC
Frame
Valid
Line
Valid
Integrate
Enabled
DRAFT
Exposure
(Timer 1)
> 1 µs
1001
1002
1003
1004
1
2
3
Timing
charts are
not drawn to
scale.
BASLER A202
k

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents