4.2.7 Camera Status Command

Purpose:
Type:
Read Command:
Response:
Data Format:
k
BASLER A202
The camera has been programmed to detect several error conditions. When an error
condition is detected, a flag is set. The status command allows you to read the error flags.
This is a read only command.
Cmd-ID
0x43
Cmd-ID
0x43
Byte 1
Byte 2
Byte 1
Bit 0
No ExSync signal in the last 5 seconds
Bit 1
A reset has occurred.
Bit 2
The camera is unlocked
Bit 3
Reserved
Bit 4
Unknown command ID specified in a read or write command
Bit 5
A read or write command could not be executed;
access denied
Bit 6
The length member of the last command does not match
the defined length
Bit 7
Parameter error
(currently has no meaning - reserved for future use)
Byte 2
Bit 0
FPGA; general error
Bit 1
FPGA; no FPGA firmware available
Bit 2
No FPGA/ADC command list available
Bit 3
Error in FPGA/ADC command list item
Bit 4
User set is erroneous
Bit 5
Factory set is erroneous
Bit 6
EEPROM checksum error (this is a checksum used to
determine if the contents of the EEPROM are valid)
Bit 7
No EEPROM command list available
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
Each bit specifies an error condition (see table below).
If a bit is set to 1, the error condition assigned to that bit
is present. If the bit is set to 0, the error is not present.
Each bit specifies an error condition (see table below).
If a bit is set to 1, the error condition assigned to that bit
is present. If the bit is set to 0, the error is not present.
Configuring the Camera
Data
2
-
Data
2
2 Bytes
4-27