Installing Output Devices; Figure 3-21: 4204 Relay Module; Figure 3-22: 4204Cf Relay Module - Honeywell VISTA-128BP Installation And Setup Manual

Commercial burglary partitioned security systems
Hide thumbs Also See for VISTA-128BP:
Table of Contents

Advertisement

Installing Output Devices

The VISTA-128BP/VISTA-250BP support up to 96
outputs. Each device must be programmed as to how
to act (ACTION), when to activate (START), and when
to deactivate (STOP). The 4204, 4204CF, FSA-8, FSA-
24, 4140SN and/or X-10 devices may be used as output
devices.
Installing 4204 and 4204CF Relay Modules
Each 4204 module provides 4 relays with Form C
(normally open and normally closed) contacts. Each
4204CF module adds two style Y supervised bell
outputs to the system. For 4204CF modules, only
relays 1 and 3 on each module can be programmed.
The relay module will not operate until the
device address you have set the DIP switches
for is enabled in the control's Device
Programming in the #93 Menu Mode .
To install the relay modules, see Figures 3-21 and 3-22
and perform the following steps:
Step
Action
1
Set the 4204 or 4204CF's DIP switches for a
device address 01-15.
Do not use an address being used by another
device (keypads, RF receivers, etc.).
2
Mount the 4204 and 4204CF Modules per the
instructions provided with them.
3
Connect the module's wire harness to the
control (6, 7, 8, and 9). Plug the connector
(other end of harness) to the module.
If you are mounting remotely, homerun each
module to the control. The table below shows
the maximum wire run lengths. Refer to the
instructions provided with the 4204CF for its
maximum permissible wire lengths.
Wire Gauge
#22
#20
#18
#16
Installing FSA Modules
The 8-zone LED Fire System Annunciator FSA-8 and
24-zone LED Fire System Annunciator FSA-24 enable
a fire response unit to identify quickly the point/zone
of a fire. These indicators may be used for other
functions as well, such as status indication. A
maximum of 4 FSA modules, in any combination, can
be supported.
The FSA module will not operate until the
device address you have set the DIP switches
for is enabled in the control's Device
Programming in the #93 Menu Mode .
WWW.DIYALARMFORUM.COM
Maximum Length
125 feet
200 feet
300 feet
500 feet
WWW.DIYALARMFORUM.COM
Section 3 - Installing the Control
SWITCH
©
POSITION
OFF
ON
0
1
2
2
ON
ON
3
ON
ON
4
ON
ON
ON
ON
5
ON
ON
ON
ON
4204
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
4-PIN CONSOLE PLUG
EITHER OR BOTH
CAN BE USED
TB1
13 14 15 16
YEL
BLK
GRN
RED

Figure 3-21: 4204 Relay Module

SWITCH
4 2 0 4 C F A D D R E S S S E T T I N G S
©
POSITION
OFF
ON
0
1
2
3
2
ON
ON
3
ON
ON
4
ON
ON
ON
ON
5
ON
ON
ON
ON
DIP SWITCH
FOR SETTING DEVICE
ADDRESS AND
ENABLING/DISABLING
TAMPER
COVER TAMPER (REED) SWITCH
4-PIN CONSOLE PLUG
EITHER OR BOTH
CAN BE USED
TB1
13
14
15
16
YEL
DATA IN
FROM CONTROL
BLK
(–) GROUND
GRN
DATA OUT
TO CONTROL
RED
(+) 12V; SUPPLIES POWER TO MODULE
CIRCUITRY (INCLUDING NOTIFICATION
APPLIANCE RELAY COILS). CURRENT
DRAIN AT 12V IS: 25 mA + (80 mA PER
ACTIVE OUTPUT)

Figure 3-22: 4204CF Relay Module

To install the FSA module, refer to Figure 3-23 and
perform the following steps:
Step
Action
1
Set the FSA's DIP switches for a device
address from 08 to 23. See the module's
instructions for the DIP switch table.
Do not use an address being used by
another device (keypads, RF receivers, etc.).
2
Mount the FSA module horizontally to a
duplex box (quad box for FSA-24).
3
Connect the module to the control's keypad
terminals (6, 7, 8, and 9).
4 2 0 4 A D D R E S S S E T T I N G S
("—" means "OFF")
3
4
5
6
7
8
9
10
11
12
13
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
RELAY
C
4
NC
TYPICAL
NO
(SHOWN "OFF")
C
RELAY
3
NC
NO
C
RELAY
2
NC
NO
C
RELAY
1
NC
NO
L
TB2
DATA IN
FROM CONTROL
(–) GROUND
DATA OUT
TO CONTROL
(+) 12V
("—" means "OFF")
4
5
6
7
8
9
10
11
12
13
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
- ALARM POLARITY
SHOWN
- EACH OUTPUT
NOTIFICATION
NC
PROVIDES
APPLIANCE B
STYLE Y
2K EOLR
NC
SUPERVISION
#610-7
+
- EACH OUTPUT
RATED 1.2A MAX
POLARIZED
NC
NOTIFICATION
- USE
NC
APPLIANCE
NOTIFICATION
APPLIANCES
COMPATIBLE
NOTIFICATION
WITH
APPLIANCE A
NOTIFICATION
2K EOLR
APPLIANCE
#610-7
+
POWER SUPPLY
VOLTAGE
NC
RATING
}
POWER FOR
NC
NOTIFICATION APPLIANCE A,
NOTIFICATION APPLIANCE B
L
8-28VDC OR VFW. UP TO 2.4A
TB2
DEPENDING ON BELL CURRENT
NOTIFICATION APPLIANCE AND
CONSOLE DATA OUTPUTS ARE
POWER LIMITED
14
15
ON
14
15
ON
3-17