Open/Close Schedules Definitions - Honeywell VISTA-128BP Installation And Setup Manual

Commercial burglary partitioned security systems
Hide thumbs Also See for VISTA-128BP:
Table of Contents

Advertisement

Open/Close Schedules Definitions

General
The open/close scheduling is controlled by one of three
schedules. Each schedule consists of one time window
for openings and one time window for closings.
There are three types of schedules available: Daily,
Holiday, and Temporary.
Daily Schedule
Each partition can have one daily schedule consisting
of one opening window and one closing window per
day.
Holiday Schedule
A holiday schedule overrides the regular daily schedule
on selected holidays throughout the year.
The opening and closing windows are programmed in
the daily schedule, but the holidays themselves are
defined in Holiday Schedule Programming in the #80
Menu Mode.
Temporary Schedule
The temporary schedule provides a method for the end
user to override the daily and holiday schedules. It
consists of one opening window and one closing
window for each day of the week. The schedule takes
effect for up to one week, after which it is
automatically deactivated.
This schedule is programmed using the #81 Temporary
Schedule Menu Mode.
Example of Open/Close Exception Reporting & Scheduling
The following chart gives an example of how the Open/Close by Exception reporting works.
6:01PM
5:59AM
Early Opening reports are
sent if system is manually
disarmed before opening
window begins.
Early and Late Opening
and Closing reports are
programmable options
in the Report Code
Programming. They are
not dependent on the
programming of the
Exception Reporting
option.
WWW.DIYALARMFORUM.COM
6AM
9AM
9:01AM
Auto-disarm delay begins.
Opening Window
Auto-disarm occurs after delay (if
No reports are sent if
auto-disarm is enabled).
system is disarmed
Missed Opening reports are sent if
during this time
manual disarming has not
window.
occurred at expiration of opening
window.
If an arming occurs,
a Closing report is
Late Opening reports are sent if
sent to the central
disarm occurs after the opening
station regardless of
window expires.
how the Exception
Early Closing reports are sent if
Reporting option is
manual arming occurs before the
set.
closing window begins.
Missed Opening/Closing type
reports are programmed in the
Report Code Programming. The
Exception Reporting option
must be set for these to be
sent.
WWW.DIYALARMFORUM.COM
Section 6 – Scheduling Options
Additional Schedules
Additional opening and closing schedules can be
programmed using the Time-Driven Event
Programming. For example, a schedule for normal
store openings/closings can be programmed with a
daily open/close schedule, and another open/close
schedule for a lunch hour can be programmed using
the Time-Driven event schedule programming.
Refer to "Time-Driven Events" later in this section for
detailed information.
Open/Close Reports by Exception
The system can help reduce communication traffic to
the central station by using the Open/Close Reports by
Exception feature. The Open/Close by Exception
option suppresses these reports from being sent to the
central station if an arm or disarm is done within the
expected time window. Reports are only sent if the
arm or disarm occurs outside the assigned time
window.
The system keeps a record of all openings/closings in
its event log.
If a disarming occurs during a closing window (for
example, a person who arms the system forgets
something and has to re-enter), the Opening report
(although outside of the opening window) will not be
sent (as long as that disarming occurs within the
closing window).
This option is programmed in partition-specific
program field 2*09.
3:59PM
4PM
Closing Window
No reports are sent
if system is armed*
during this time
window.
* or disarmed if user
needs to re-enter
premises.
6PM 6:01PM
5:59AM
Auto-arm delay begins.
Auto-arm warning begins.
Auto-arm occurs after
warning expires (if auto-arm
is enabled).
Missed Closing reports are
sent if manual arming has
not occurred at expiration of
closing window.
Late Closing reports are
sent if system is manually
armed after the closing
window expires.
6-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bpVista-128sia

Table of Contents