VISTA-128BP/VISTA-250BP Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Zone 5 Audio Alarm Verification
1*60
0 = disable
1 = enable
Printer Type
1*69
0 = parallel printer
1 = serial printer
Event Log Types
1*70
0 = disable
1 = enable
12/24 Hour Type Stamp Format
1*71
0 = 12-hour
1 = 24-hour
Event Log Printer On-Line Mode
1*72
0 = disable
1 = enable
Printer Baud Rate
1*73
0 = 1200
1 = 300
Relay Timeout XXX Minutes
1*74
Enter 000-127 times 2 minutes (000-254).
Relay Timeout YYY Seconds
1*75
Enter 000-127 seconds.
Access Control Relay (partition-
1*76
specific)
01-96 = relay number
00 = relay not used.
Number of Partitions
2*00
Enter 1-8.
Daylight Saving Time Start/End
2*01
Month
0 = disable
1 = enable
Daylight Saving Time Start/End
2*02
Weekend
0 = disable
1 = enable
U L
Fields 2*05 – 2*08 must be set to 0 for UL installations.
5-12
WWW.DIYALARMFORUM.COM
EXPLANATION
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
NOTE: Zone 5 cannot be used as protection zone.
Select the printer type for the event log printout.
NOTE: if you are using a parallel printer connected to the VA8201 Alpha Pager
Module.
This field has five entries as follows: Alarm, Check, Bypass, Open/Close,
System. If enabled, the system logs those events into the event log.
NOTE: Events are also logged into the PassPoint system, if installed.
Select the type of time stamping for the event log.
If enabled, the system prints the events as they occur.
If disabled, the system prints the log only upon request.
Select the baud rate for the serial printer.
NOTE: Must be 1 if using the alphanumeric pager interface.
This is used for #80 Menu Mode Time-Driven event relay command numbers
"04/09" and Output Programming in the #93 Menu Mode Programming output
command "56."
This is used for #80 Menu Mode Time-Driven event relay command numbers
"05/10" and Output Programming in the #93 Menu Mode Programming
command "57."
If enabled, the assigned relay closes for 2 seconds when the user enters his
code and presses 0.
Must be 00 for UL installations.
NOTE: See SECTION 3: Installing the Control for enhanced access control
capabilities.
Enter the number of partitions used in the system.
Enter the months (00-12) in which daylight saving time starts and ends.
Enter 00, 00 if daylight saving time does not apply to the user's region.
Standard setting for U.S. is 04,10.
Enter the start and end weekends for daylight saving time as follows: 1=first;
2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard
setting for U.S. is 1,5.