VISTA-128BP/VISTA-250BP Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Entry Delay #1 (partition-specific)
*09
Enter 02-15 multiplied by 15 seconds.
00 = no delay.
Exit Delay #1 (partition-specific)
*10
Enter 03-15 multiplied by 15 seconds.
00 = no delay.
Entry Delay #2 (partition-specific)
*11
Enter 02-15 multiplied by 15 seconds.
00 = no delay.
Exit Delay #2 (partition-specific)
*12
Enter 03-15 multiplied by 15 seconds.
00 = no delay.
Alarm Sounder Duration
*13
(partition-specific)
Enter 01-15 multiplied by 2 minutes.
00 = no timeout.
Burglary or RS232 Input
*14
0 = burglary
1 = RS232 input
U L
Using the RS232 input for automation is not permitted in UL installations.
Keyswitch Assignment
*15
Enter 1-8 partition keyswitch is being used.
Enter 0 if the keyswitch is not used.
Confirmation of Arming Ding
*16
(partition-specific)
0 = disable
1 = enable
AC Loss Keypad Sounding
*17
0 = disable
1 = enable
Randomize AC Loss Report
*19
0 = disable
1 = enable
5-2
WWW.DIYALARMFORUM.COM
EXPLANATION
Entry delay defines the delay time that allows users to re-enter the premises
through a door that has been programmed as an entry delay door and disarm
the system without sounding an alarm. The system must be disarmed within this
period or an alarm will occur.
NOTE: The delay may not exceed 45 seconds for UL installations. SIA
Guidelines: The entry delay time and Burg Alarm Comm Delay (field *88)
combined cannot exceed 1 minute.
Exit delay defines the delay period that allows users to leave the premises
through a door that has been programmed as an entry/exit delay door after
arming the system without setting off the alarm.
NOTE: SIA Guidelines: The delay must be set for a minimum 45 seconds.
Entry Delay #2 is used for a secondary door requiring a longer delay than those
assigned to Entry Delay #1.
NOTE: The delay may not exceed 45 seconds for UL installations. SIA
Guidelines: The entry delay time and Burg Alarm Comm Delay (field *88)
combined cannot exceed 1 minute.
Exit Delay #2 is used for a secondary door requiring a longer delay than those
assigned to Exit Delay #1.
NOTE: The delay may not exceed 60 seconds for UL installations. SIA
Guidelines: The delay must be set for a minimum 45 seconds.
Defines the length of time the Bell Output and the keypad's sounder will sound
for all audible alarms.
Must be minimum 16 minutes for UL Commercial Burglary installations. SIA
Guidelines: Must be minimum 6 minutes.
If enabled, sets terminal 23 (high side (+) of zone 9) as an RS232 input. This
enables the system to receive serial data (75 baud) via terminal 23.
The keyswitch requires the use of zone 7 wired loop (zone 7 is no longer
available as protection zone). The fire and panic alarm voltage triggers (J7)
automatically become ARMING and READY status outputs for the Keyswitch
LEDs.
Openings/closing report as user "0" if enabled in field *40.
If enabled, produces ½-second external alarm sounding ("ding") at the end of
exit delay (or after kissoff from the central station, if sending closing reports).
Must be 1 for UL installations.
If enabled, sounding at the keypad (rapid beeping) occurs when AC power is
lost (sounding occurs about 2 minutes after actual AC loss).
If enabled, randomizes AC loss reporting between 10 and 40 min. after an
actual AC loss.
If disabled, AC loss reporting about 2 minutes after actual AC loss.
Selecting this option helps prevent an overload of AC loss messages at the
central station during a community blackout.