VISTA-128BP/VISTA-250BP Installation and Setup Guide
ACTION CODES
06=Relay Group On
07=Relay Group Off
08=Relay Group Close for 2
seconds
09=Relay Group Close XX
minutes
10=Relay Group Close YY
seconds
20=Arm-STAY
21=Arm AWAY
22=Disarm
23=Force Arm STAY
24=Force Arm AWAY
25=Arm INSTANT
26=Arm MAXIMUM
40=Enable Open Window by
Part.
41=Enable Close Window by
Part.
30=Auto bypass – Zone list
31=Auto unbypass – Zone list
42=Enable Access Window for
Access group(s)
55=Access Point Grant
56=Access Point Grant
w/Override
57=Access Point Protect
58=Access Point Bypass
59=Access Point Lock
60=Access Point Exit
61=Access Point Group Grant
62=Access Point Group Grant
w/Override
63=Access Point Group
Protect
64=Access Point Group
Bypass
65=Access Point Group Lock
66=Access Point Group Exit
77=Access Point Group Enable
78=Access Point Group
Disable
6-10
WWW.DIYALARMFORUM.COM
EXPLANATION
Actions 06-10
If you selected actions 06-10, the prompt at the right appears. Enter the relay
group number.
Press [✳] to accept entry. The "Time Window ?" prompt appears.
Actions 21-26 and 40-41
If you selected actions 21-26 or 40-41, the prompt at the right appears. Enter
the partition to which the action applies. Enter 0 to select all partitions. Enter a
partition number again to deselect it.
Press [✳] to accept entry. The "Time Window ?" prompt appears.
Actions 30-31
If you selected actions 30-31, the prompt at the right appears. Enter the zone
list number that contains the zones to be bypassed or unbypassed.
Press [✳] to accept entry. The "Time Window ?" prompt appears.
Action 42
If you selected action 42, the prompt at the right appears. Enter the group
number to which the time window will apply.
Press [✳] to accept entry. The "Time Window ?" prompt appears.
Actions 55-60
If you selected actions 55-60, the prompt at the right appears. Enter the access
point number.
Press [✳] to accept entry. The "Time Window ?" prompt appears.
Actions 61-66 and 77-78
If you selected actions 61-66, the prompt at the right appears. Enter the group
number.
Press [✳] to accept entry. The "Time Window ?" prompt appears.
WWW.DIYALARMFORUM.COM
ACTION SPECIFIER
01 RELAY GRP # ?
00
PART? 12345678
HIT 0-8
X X
01 ZONE LIST ?
ENTER 01-15
01
GROUP ? 12345678
HIT 0-8
X
01 ACCESS POINT #
000
01
GROUP #
00