Type 06 Serial Number Polling Loop (SL)
Select for polling loop devices with a built-in serial
number.
For VistaKey, select this type for Door Status Monitor
Backup DSMB. If local power to the VistaKey is lost, a
V-Plex SIM, located on the VistaKey board, is powered
directly from the polling loop and reports the state of
the DSM via the standard V-Plex polling system.
NOTE: To obtain the DSMB function, the Input Type
must be defined as 06 and the next prompt in Zone
Programming (Access Point) must contain the Access
Point number (01-15) (address of the VistaKey
module).
Type 07 DIP Switch Loop (DP)
Select for polling loop devices that use DIP switches
for programming the zone number of the device.
Type 08 Dip Switch Polling Loop Right Loop (PS)
Select for the second loop of two-zone polling loop
devices (e.g., 4190WH; 4278).
Type 09 Console Input (CS)
Select when this zone is to be controlled by a keypad
input (user code + [#] + [7] + [3]) for access control.

Programming for Panel Linking

Step
Action
1
Program the Panel Link Module (PLM) into
the system in Device Programming in the #93
Menu Mode with Device Type 10.
2
If you want to supervise the PLM,
program zone 8xx with response type 05,
where "xx" = the module's address. If you
want the zone to report to the central station,
make sure the report code for the zone is set
with a non-zero value.

Programming for the Alpha Pager Module

✳05 Enter 1 to print all zone faults/restores; enter
0 to print only events enabled in field 1✳70
✳14 Enter 1 if using Home Automation
1✳69 Printer selection 0 for parallel; 1 for serial
1✳70 Event Log Types (1=enable; 0=disable)
1✳71 12/24-Hour Time Stamp (0=12 hr; 1=24 hr)
1✳72 Printer On-line (must be 1 (enable) for APM)
1✳73 Enter 0 for 1200 Baud Rate
4-8
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Type 10 PassPoint Access Control (ACS)
Select when this zone is mapped to a zone on the
PassPoint Access Control System.
Type11 VistaKey Door Status Monitor (DSM)
Select this input type when using a VistaKey module
connected to a door. This must be programmed for
each VistaKey module to provide the DSM zone
mapping a panel zone. If this is not programmed the
panel will not "see" the VistaKey module.
It is also used to determine the door is opened after a
card swipe or if the door is being held open. The
device is normally a magnetic switch mounted on the
door. The status of the switch is different when the
door is in an open position.
Type 12 VistaKey Request to Exit (RTE)
Use this input type to map an uncommitted RTE zone
to an alarm panel zone. This input type is not normally
used if the zone is used for a request-to-exit function.
Type 13 VistaKey General Purpose (GP)
This input type operates in the same manner as other
VISTA-128BP/VISTA-250BP alarm panel zones and is
provided so that a zone in the proximity of the
VistaKey can be wired without having to run
additional wiring from the control panel.
Step
Action
3
If you want to supervise the PLMs
connected to other controls, program
those modules in Zone Programming with
response type 14. Also, program the panel ID
number. The ID number must match the ID
number programmed in Device Programming
of the control panel the PLM is connected. If
you want the zone to report to the central
station, make sure the report code for the
zone is set with a non-zero value. Be sure to
program the input type with 00.
See Device Programming and Zone Programming in
#93 Menu Mode Programming in the Programming
Guide for a detailed explanation of the programming
procedures.
2✳30 Enter 1 to enable the Alpha Pager Module.
2✳31 - 2✳88 Paging service parameters. The
events (e.g., field 2*39) must be programmed
for the pager to work.
Fields for programming the delay times (e.g.
2*36 and 2*37 for pager 1) are relevant only
when using numeric format for the pager.
NOTE: For Event Log Report Codes program
System Group #2 in the #93 Menu Mode.