VISTA-128BP/VISTA-250BP Installation and Setup Guide

Features

Hardwire and Optional Expansion Zones
Provides 9 hardwire zones.
Supports up to 16 2-wire smoke detectors on zone 1.
Automatically resets 4-wire smoke detectors using the J7 output when a code + off is entered.
Triggers the built-in sounders on other hardwired smoke detectors if one smoke detector annunciates an alarm.
This feature requires a 4204 Relay Module and/or the 333PRM.
Provides tamper supervision on the hardwire zones.
Supports up to 50 2-wire latching glassbreak detectors on zone 8.
Supports up to 241 additional expansion zones (119 for the VISTA-128BP) using a built-in polling (multiplex) loop.
Supports up to 250 wireless zones (128 for the VISTA-128BP) (fewer if using hardwire and/or polling loop zones).
The 5881ENHC RF Receiver and the 5869 Holdup Switch Transmitter are listed for UL Commercial Burglary
U L
applications. All other RF receivers and transmitters are not listed for UL Commercial Burglary applications.
Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not
display or sound the alarm).
Provides three keypad panic keys: 1 + ✴ (A), ✴ + # (B), and 3 + # (C).
Peripherals Devices
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system
zones (RF receivers and keypad panics).
Provides 96 outputs using 4204 and 4204CF Relay Modules, Fire System Annunciators (FSA-8, FSA-24), V-Plex
Relay Modules and X-10 devices can activate outputs in response to system events (alarm condition), at a specific
time of day, at random times, and manually using the #70 Relay Command Mode.
Supports the ADEMCO 4285/4286 VIP Module, which allows access to the system from either a remote location or
on the premises
U L
The VIP Module is not Listed for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation.
Supports the ADEMCO 4146 Keyswitch on any one of the system's 8 partitions.
Arming/Disarming and Bypassing
Can arm the system with zones faulted (Vent Zone). These zones are automatically bypassed and can be
programmed to automatically unbypass when the zone restores.
Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must be restored before the
exit delay expires, otherwise an alarm is generated.
Vent zones cannot be used in UL installations.
U L
You must disable the Force Arm option (used in conjunction with the Arm w/Fault option), in UL installations.
Provides global arming capability (ability to arm all partitions the user code has access to in one command).
Can Quick Exit an armed premises without having to disarm and then rearm the system.
U L
Quick Exit is not permitted for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation.
1-2
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM