Following is a list of commands used while in the Menu Mode:
#93
Enters Menu Mode.
[✳]
Serves as [ENTER] key. Press to have keypad accept entry.
[#]
Backs up to previous screen.
0
Press to answer NO.
1
Press to answer YES.
Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu option.
00, or 000+[✳]

Zone Number Designations

The VISTA-128BP supports up to 128 zones, the
VISTA-250BP supports up to 250 zones, of hardwire,
polling loop and/or wireless protection, distributed
among up to 8 partitions. The following table lists the
zone numbers and the types of sensors that can be
used with each, and some alternate functions of the
zones.
Zone
Function
1
2-wire Smoke Detectors (if used)
5
Audio Alarm Verification (if used)
7
Keyswitch (if used)
8
Latching-Type Glassbreak Detectors (if used)
1-9
Traditional Hardwired Zones
9
RS232 Input (if used)
1-250
5800 Series Wireless Devices
10-250
Polling Loop Devices
✳ + 1 Panic
995
996
# + 3 Panic
✳ + # Panic
999
Zone Defaults
Zone #
Zone Type
001
09
002
03
003
03
004**
04
005
03
006
03
007
03
008
03
009
03
010–250
00
NOTES:
* Zone 992 is the Duress zone. Programming of the zone
response type is not applicable. This zone requires only the
report code programming.
** Zone 004 is also defaulted with Auto-STAY enabled.
4-4
WWW.DIYALARMFORUM.COM
#93 Menu Mode Programming Commands
Zone #
Zone Type
601-632
00
800-830
00
970
00
988
00
990
00
992*
N/A
995
00
996
00
997
05
999
06
WWW.DIYALARMFORUM.COM
Zone Index
The zones are designated as follows:
ZONE #
ZONE
RANGE
FUNCTION
001 – 250
Protection
zones
601 – 632
Relay
Supervisory
Zones
800 – 830
ECP Device
Supervisory
Zones
970, 988,
System
990, & 997
Supervisory
Zones
992, 995 –
Duress and
999
Keypad
Panics
Program supervisory zones with response type of 05.
Communication Defaults
*45
PRIMARY FORMAT
*46
LOW SPEED FORMAT (Prim)
*47
SECONDARY FORMAT
*48
LOW SPEED FORMAT (Sec.)
*49
CHECKSUM VERIFICATION
No checksum
*50
SESCOA/RADIONICS SEL.
*51
DUAL REPORTING
*52
STANDARD/EXPANDED REPORT FOR PRIMARY
[0]
[0]
[0]
Alarm Rstr
Bypass
*53
STANDARD/EXPANDED REPORT FOR SECONDARY
[0]
[0]
[0]
Alarm Rstr
Bypass
ACTUAL ZONE
As indicated
6 + 2-digit Relay Number; e.g.,
Relay Number 03 is zone 603.
8 + 2-digit Device Address; e.g.,
Device Address 01 is zone 801.
VIP Module is zone 804 (Device
Address must be set to 4).
TeleSmart is zone 824 (Device
Address must be set to 24).
970:
Bell Supervision
nd
988:
2
Wireless Receiver –
not receiving signals
st
990:
1
Wireless Receiver –
not receiving signals
997:
Polling Loop (short circuit)
992:
Duress
1 + ✳ panic (A key)
995:
996:
3 + # panic (C key)
✳ + # panic (B key)
999:
[1]
ADEMCO Contact ID
[0]
ADEMCO Low Speed
[1]
ADEMCO Contact ID
[0]
ADEMCO Low Speed
[0]
[0]
Primary
Secondary
[0]
Radionics
[0]
no
[0]
[0]
[0]
standard
Trbl
Opn/Cls Low Bat
[0]
[0]
[0]
standard
Trbl
Opn/Cls Low Bat