Honeywell VISTA-128BP Installation And Setup Manual page 71

Commercial burglary partitioned security systems
Hide thumbs Also See for VISTA-128BP:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Swinger Suppression (partition-
*84
specific)
Enter 01-15.
Enter 00 for unlimited reports
Enable Dialer Reports for Panics
*85
& Duress (partition-specific)
0 = disable
1 = enable
Entry Warning (partition-specific)
*87
0 = 3 short beeps
1 = slow continuous beeps
Burglary Alarm Communicator
*88
Delay (partition-specific)
0 = no delay
1 = 30-second delay
Restore Report Timing
*89
0 = instant
1 = after bell timeout
2 = when system is disarmed
Secondary Subscriber Account
*90
Number (partition-specific)
Enter 00-09; B-F (11-15)
Check or TRBL Display
1*07
0 = CHECK
1 = TRBL
First to Alarm Display Lock
1*10
0 = scroll alarms
1 = lock display
Cancel Verify
1*15
0 = disable
1 = enable
Lobby Partition
1*17
0 = none
1-8 = partition number
Affects Lobby (partition-specific)
1*18
0 = disable
1 = enable
WWW.DIYALARMFORUM.COM
EXPLANATION
This option limits the number of messages (alarms or troubles) sent for a
specific zone in an armed period. The system automatically resets the
shutdown for a zone after 48 hours if there are no trips on any zone.
Must be 00 for UL installations.
This field has four entries as follows: Zone 995, 996, 999, Duress Enable for
each partition that the panics and duress reporting is desired.
NOTE: Non-zero report code must be assigned to zone 992 (duress) to enable
Duress reporting.
If you enable any of the panics to report, make sure field *22 is programmed
correctly for each partition.
Select the type of warning for the entry delay period.
Select the delay, if any, for burglary alarm communications.
Must be 0 for UL installations.
SIA Guidelines: Must be 1.
Select the time when restore reports are sent after an alarm.
Must be 2 for UL installations.
Enter a 3- or 4-digit (depending on report format) primary subscriber account
number. Each number requires a 2-digit entry so as to allow entry of
hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data
only in the first 3 locations, and enter * in the fourth location.
NOTE: This field must be programmed if a secondary phone number is used
(field *34). This account number can be the same as the primary account
number.
Select whether the system should display TRBL or CHECK for trouble
conditions.
If lock display is selected, the system displays of first fire alarm and requires the
user to press the [*] key for a display of each additional fire alarm. Otherwise,
the system automatically scrolls all fire alarms.
If enabled, the system pulses the alarm output three times and displays "Cancel
Sent to Central Station" when it receives a "kissoff" of a Cancel report from the
central station This message can only be cleared by entering the code + off.
Enter 0 to disable.
NOTE: Field 1✳52 determines when a Cancel report is sent to the central
station.
Select the Common Lobby Partition.
If enabled, causes lobby partition to disarm when this partition disarms.
NOTE: This partition must be armed before lobby can be armed.
WWW.DIYALARMFORUM.COM
Section 5 – Data Field Descriptions
5-7