VISTA-128BP/VISTA-250BP Installation and Setup Guide
1.
Enter the schedule number (01-20) and time
window number (01-20), and note the day of the
week the action is desired.
2.
Enter the code for the desired action and
action specifier. The action codes represent the
events that are to take place when the scheduled
time is reached. Each action also requires an
action specifier, which defines what the action will
affect (relay, relay group, partition, zone list, user
group). The action specifier varies, depending on
the type of action selected.
The following is a list of the Action Codes (desired
actions) used when programming Time-Driven
events. Note that these codes are independent of
the relay codes programmed during Output
Programming in the #93 Menu Mode.
Relay Commands
Action Code
Action
01
Relay On
02
Relay Off
03
Relay Close for 2 seconds
Relay Close XX minutes (set
04
in field 1*74)
Relay Close YY seconds (set
05
in field 1*75)
06
Relay Group On
07
Relay Group Off
Relay Group Close for 2
08
seconds
Relay Group Close XX
09
minutes (set in field 1*74)
Relay Group Close YY
10
seconds (set in field 1*75)
Arm/Disarm Commands
Action Code
Action
20
Arm-STAY
21
Arm AWAY
22
Disarm
Force Arm STAY (Auto-
23
bypass faulted zns)
Force Arm AWAY (Auto-
24
bypass faulted zns)
25
Arm INSTANT
26
Arm MAXIMUM
The auto-arm warning (field 2*06) applies
when using Time-Driven events to auto-arm.
Temporary schedules do not override an
auto-arming or auto-disarming programmed
in Time-Driven events.
The auto-arming window cannot be
extended using the Installer Code + #82
Mode.
6-8
WWW.DIYALARMFORUM.COM
Action Specifier
Relay #
Relay #
Relay #
Relay #
Relay #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Action Specifier
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
WWW.DIYALARMFORUM.COM
Bypass Commands
Action Code
Action
30
Auto bypass – Zone list
31
Auto unbypass – Zone list
Open/Close Windows
Action Code
Action
Enable Opening Window by
40
partition
Enable Closing Window by
41
partition
Enable Access Window for
42
access group
Access Control Commands
Action Code
Action
55
Access Point Grant
Access Point Grant with
56
Override
57
Access Point Protect
58
Access Point Bypass
59
Access Point Lock
60
Access Point Exit
61
Access Point Group Grant
Access Point Group Grant
62
with Override
63
Access Point Group Protect
64
Access Point Group Bypass
65
Access Point Group Lock
66
Access Point Group Exit
67
Access Point Partition Grant
Access Point Partition Grant
68
with Override
Access Point Protect by
69
Partition
Access Point Bypass by
70
Partition
71
Access Point Lock by Partition
72
Access Point Exit by Partition
73
Access Point Trigger On
74
Access Point Trigger Off
77
Access Point Group Enable
78
Access Point Group Disable
Action Specifier
Zone list #
Zone list #
Action Specifier
Partition(s)
Partition(s)
Access Group
Action Specifier
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Group #
Group #
Group #
Group #
Group #
Group #
Partition #
Partition #
Partition #
Partition #
Partition #
Partition #
Trigger #
Trigger #
Group #
Group #

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bpVista-128sia

Table of Contents