Honeywell VISTA-128BP Installation And Setup Manual page 9

Commercial burglary partitioned security systems
Hide thumbs Also See for VISTA-128BP:
Table of Contents

Advertisement

Can be armed in one of three STAY modes or Instant modes, automatically bypassing specific burglary zones
regardless of the zone response type.
Can automatically bypass specific zones if no one exits the premises after arming (Auto-STAY). Auto-STAY will
not occur if the system is armed via an RF transmitter, VIP module, scheduling, access control, keyswitch, RS232
automation or downloading.
Can bypass a group of zones with one set of keystrokes.
Supports Exit Error Logic, whereby the system can tell the difference between a regular alarm and an alarm
caused by leaving an entry/exit door open. If the system is not subsequently disarmed, faulted E/E zone(s) and/or
interior zones are bypassed and the system arms.
Supports Recent Close report, which is designed to notify the central station that an alarm has occurred within 2
minutes after the exit delay has expired.
Partitioning and Panel Linking
Can control 8 separate areas independently, each functioning as if it had its own separate control.
Provides a Common Lobby partition, which can be programmed to arm automatically when the last partition is
armed, and to disarm when the first partition is disarmed.
Provides a Master partition (9), used for the purpose of viewing the status of all partitions at the same time.
Can display fire, burglary, panic and trouble conditions at all other partitions' keypads (selectable option).
Can "link" together up to 8 control panels. This allows users to access and control from a keypad another control
panel.
Scheduling
Can automate system functions, such as arming, disarming, and activation of outputs (e.g., lights).
Provides access schedules (for limiting system access to users by time).
Provides an End User Output Programming Mode, allowing the user to control outputs.
Access Control
Supports up to 15 VistaKey modules (15 access points) (VISTA-128BP supports 8 modules), which are used for
access control. It is a single-door access control module.
Support up to 500 access cards.
Supports ADEMCO PassPoint system via one VISTA Gateway Module (VGM), for a fully integrated access control
system.
Can store access control events in the event log.
System Communication
Supports ADEMCO Contact ID; ADEMCO High Speed; ADEMCO Express; and 3+1, 4+1, and 4+2 ADEMCO and
Sescoa/Radionics Low-Speed formats.
The system is shipped defaulted for Contact ID communication. It is the only format capable of uniquely reporting
all 250 zones, as well as openings and closings for all 250 users. This requires central stations to be equipped with
the ADEMCO 685 receiver using software level 4.10 or higher to fully support all new VISTA-128BP/VISTA-250BP
report codes. If you need to update your 685 receiver, contact your distributor.
Can send messages such as alarms, opens/closes, etc. to up to 8 paging services.
Provides two paging formats (alphanumeric – requires the VA8201 Alpha Pager Module; and numeric – sent
directly by the control)
Supports Dynamic Signaling feature, which prevents redundant signals being sent to the central station when
both the built-in dialer and Long Range Radio are used.
Provides an Audio Alarm Verification (AAV) option that permits voice dialog between an operator at the central
station and a person at the premises. An AAV unit, such as ADEMCO UVS, is required.
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Section 1 - General Description
1-3