5.5 How to clean the rollers in the ADF

If the document feeding rollers in the ADF are contaminated with ink, toner particles or
paper dust, documents and outputs get dirty and a paper jam and noise may occur. To
prevent this, it is recommended to clean the rollers once a month.
(1) Turn off the power of MFP.
(2) Open the ADF cover.
(3) Open the roller cover.
45387101TH Rev.1
Roller cover
(4) Wipe the document feed rollers with a soft cloth lightly moistened with water.
Wipe the whole surface of the roller while turning it with your hand.
Surface of the Guide
Note! If the rollers get too dirty, wipe them with a soft cloth lightly moistened with
neutral detergent, and then wipe it again with a soft cloth lightly moistened
with water.
(5) Open the inner cover and wipe the rollers with a soft cloth lightly moistened
with water.
ADF cover
Roller
(6) Close the roller cover and ADF Cover.
5. Periodic maintenance