Toshiba e-STUDIO477S Service Manual page 38

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

(3) Install the optional tray unit and LCF unit to the MFP .
Note! Because the weight of the MFP weights is approximately 42kg, it needs more than
three adults to lift it up.
① Match the tab into the hole in the bottom of the MFP .
② Put the MFP on the optional tray unit slowly.
③ Attach the joint (2 places) to optional tray unit and screw up.
Remove it following the steps 1-2 in reverse order.
Joint
Note! When you install two or more optional trays to the MFP , set the optional tray directly
on top of the other optional tray, and then put them on the MFP .
45387101TH Rev.1
Hole in the bottom of the MFP
Tab
Screw
Joint
Joint
Joint
Hole in the bottom
Tab
Screw
Joint
Joint
2. Set up
2-9 /