Toshiba e-STUDIO477S Service Manual page 127

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

Error code
Cause
C0A6
Duplex
Fan error inside the Duplex unit.
FAN Alarm
Caution
Does the error recur when the
power is turned off once and
back on?
Does the error recur when the
power is turned off once and
back on?
C46C
Power Supply Thermistor Short
Error.
(When temperature is high)
C46D
Power Supply Thermistor Open
Error
(When temperature is low)
C46E
Power Supply Thermistor Temp
High
C46F
Power Supply Thermistor Temp
Low
CE85
LED head
Is the LED head connected
detection
normally?
error
(CE85=K)
Is the LED HEAD fuse brown?
Does this error recur?
CE7A
ID Up/Down
Is the ID unit caught by anything
position
when it is removed and re-
detection
installed?
error
Does this error recur?
45387101TH Rev.1
Error details
Remedial measure
Check if the Duplex
unit is installed
normally or not.
Check if the fans
Yes
are installed
normally or not.
Replace the fan.
Yes
Turn off the Power
of the printer and
back on.
Turn off the Power
of the printer and
back on.
Turn off the Power
of the printer and
back on.
Turn off the Power
of the printer and
back on.
No
Install the LED
head unit normally.
Yes
Check the LED
HEAD fuse.
Yes
After checking fuse
No
Turn on the power
again.
Yes
For the method of
checking the LED
head unit fuse,
refer to section 7.6.
Yes
Re-install the ID
unit.
No
Turn on the power
again.
Yes
Replace the high
voltage power supply.
Error code
Cause
C4C0
The fuse has
Is the fuser unit installed
blown out.
normally?
Does this error recur?
C383
Toner sensor
Is the toner cartridge installed?
detection
error.
Is the lock lever of the toner
(C383=K)
set?
This error
does not
occur with
the default
settings.
Does this error recur?
C44A
Thermistor
Is the error message displayed?
Slope Error
Does this error recur?
C41E
Compensation
Is the error message displayed?
Thermistor
Does this error recur?
Error
C41A
Short-circuit
or open-
C41B
circuit of fuser
Does this error recur?
thermistor is
detected.
C449
The fuser
thermistor
C446
has detected
Does this error recur?
an abnormal
temperature
Does this error recur?
(high
temperature
or low
temperature.)
6. Troubleshooting and repair procedure
Error details
Remedial measure
No
After cleaning
the connecting
connector of the
fuser unit, re-install
the fuser unit.
Turn on the power
again.
Yes
After checking
for the sure cable
connection,
Yes
replace the PU or
Board IBY.
Install the toner
No
cartridge.
Rotate the lock
No
lever of toner to the
lock position.
Turn on the power
again.
Yes
Replace the toner
sensor assembly.
Turn on the power
again.
Yes
After leaving a
printer for 30
minutes, turn on
the power again.
Turn on the power
again.
After leaving a
Yes
printer for 30
minutes, turn on
the power again.
Turn on the power
again.
Yes
Replace the fuser
unit.
Turn on the power
again.
Yes
Replace the fuser
unit.
Yes
Replace the low
voltage power
supply unit.
6-7 /

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio527s

Table of Contents