3.2.21 Cover-Assy.-St(Tall) (for finisher model only)

(1) Remove the finisher unit. (Refer to 3.2.38)
(2) Remove the Cover–Side-R. (Refer to 3.2.5)
(3) Remove the scanner. (Refer to 3.2.6)
(4) Remove the Plate-Stay-R. (Refer to 3.2.7)
(5) Remove the Plate-Board-R-Assy. (Refer to 3.2.9)
(6) Remobe the six screws (silver) ① , and remove the Cover Assy.-St (Tall) ② .
45387101TH Rev.1
(7) Remove the two screws (black) ③ , and remove the Cover-Stacker (Sub-R) ④ .
(8) Remove the two Cover-top-Sub-S ⑤ .
(9) Remove the screw (silver) ⑥ .
(10) Remove the two E rings ⑦ , and remove the Plate-Support (L-Caulking) ⑧ and
Plate-Support (R-Caulking) ⑨ .
(11) Remove the two E rings ⑩ , and remove the two Shaft-Damper (T) ⑪ and Gear-
Damper (Tall) ⑫ .
(12) Remove the four screws (silver) ⑬ , and remove the One-Way-Hinge-L ⑭ and
One-Way-Hinge-R ⑮ .