Fig. 29 Engine Sump Drain Valve - KAESER M43 Service Manual

Screw compressor
Table of Contents

Advertisement

10.3.4.1
Material
Precondition
Fig. 29
No.: 9_9432 02 E
10
Maintenance
10.3
Engine
1. Pull out the dip stick
2. Pull out the dip stick once more and read off the oil level.
3. Top up if the level is too low.
4. Reconnect the negative cable to the battery.
Starting the machine and performing a test run:
1. Start the machine and allow it to idle for at least 5 minutes.
2. Check the engine oil level.
Top up as necessary.
3. Visually inspect for leaks.
4. Shut down the machine.
Option oe
Draining engine oil via the shut-off valve
See chapter 2.6.4 for engine oil filling quantity.
Receptacle
New gasket for the drain plug
Funnel
Cleaning cloths
Machine shut down
The machine is standing level.
The machine is at operating temperature.
The machine is fully vented, the pressure gauge reads 0 bar.
All compressed air consumers are disconnected and the air outlet valves are open.
The negative cable to the battery is disconnected.
CAUTION
Danger of burns from hot components and escaping engine oil!
➤ Wear long-sleeved clothing and gloves.
Engine sump drain valve
Engine sump shut-off valve
2
Engine sump drain plug
5
1. Remove the oil filler cap.
Service Manual
Screw Compressor
M43
, wipe it clean and reinsert it.
3
Lower bodywork
7
Valve open position
8
83

Advertisement

Table of Contents
loading

Table of Contents