Air Filter Maintenance; Fig. 24 Draining The Coolant From The Radiator - KAESER M43 Service Manual

Screw compressor
Table of Contents

Advertisement

Fig. 24
Result
Further information
10.3.2
Material
Precondition
No.: 9_9432 02 E
10
Maintenance
10.3
Engine
Draining the coolant from the radiator
Radiator
1
Radiator drain plug
2
1. Have a coolant receptacle ready.
2. Unscrew the expansion tank cap (see Fig. 23).
3. Loosen and remove the drain plug
Coolant flows from the expansion tank and radiator.
➤ Dispose of used coolant in accordance with environmental protection regulations.
See the engine handbook for coolant draining from the engine block.

Air filter maintenance

The air filter must be cleaned at the latest when the corresponding maintenance indicator de‐
mands.
Renew the air filter element after 2 years at the latest or after it has been cleaned 5 times.
Compressed air for blowing out
Spare parts (as required)
The machine is shut down.
The machine is fully vented, the pressure gauge reads 0 bar.
Machine is cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
Service Manual
Screw Compressor
M43
.
2
75

Advertisement

Table of Contents
loading

Table of Contents