Cooling System; Connecting Power To And Checking The Evaporator - Accuprint AP30CL - 6000 Service Manual

Closed loop cooling high resolution printer
Table of Contents

Advertisement

2.

Cooling System

!
94MS41 Rev. C1 S/W Ver. 2.06

Connecting Power to and Checking the Evaporator

Place the evaporator flat on the floor.
Connect the hose from the evaporator to the bottom of the rear panel
drain.
Cl Make sure the hose end on the evaporator is lower than
the bottom of the rear panel drain or moisture will collect in
the bottom of the Closed Loop System.
Route the electrical cord through the channel on the left side of the unit
as shown, and connect it to the 3 pin connector marked "Evaporator"
provided inside the unit.
Note: The evaporator is on when the machine is on.
If the fan in the evaporator does not come on when the machine is turned
on, unplug the electrical connector P8 on the evaporator and check with
a voltage meter the P8 connector between pins 1 & 2 for 240V~.
If voltage is present and the blower is not running replace the blower.
If voltage is not present go to the control box and unplug the J12 connector
and measure for 240V~ between pins 3 & 4 on the board, if voltage is
present there is a brake in the cable from the board to the evaporator and
it needs to be replaced, if there is no voltage replace the 64CT464 PCB,
see section 64CT464 PCB.
Feed for
Evaporator
power cord
Evaporator
2-1