94MS41 Rev C1 S/W Ver. 2.06
Rotate the sprocket to tighten the other two screws and attach the wires.
The shutter can be tested with the unit open by disconnecting one of the
lamp leads and holding the interlock switch.
C DO NOT light the lamp without the safety glass or when
you are close to the bulb.
LT8 lampheads
Remove the four hex nuts mounting the blowers, disconnect the blower
and thermostat wires.
Remove the four screws holding the rear reflector to the cooling tubes
and remove the reflector and lamp from the lamp head.
C DO NOT TOUCH THE REFLECTOR SURFACE WITH
YOUR HANDS.
Bottom
View
Remove the three screws from the blower mounting plate to the cooling
tubes on both sides. Compress the cooling tubes into the shutter assembly,
remove the chain from the motor sprocket, then remove the shutter
assembly.
Reassemble in reverse order.
C DO NOT TOUCH THE REFLECTOR SURFACE WITH
YOUR HANDS.
End