Accuprint AP30CL - 6000 Service Manual page 21

Closed loop cooling high resolution printer
Table of Contents

Advertisement

[ U t]
[ U b]
[ L t]
[ L b]
94MS41 Rev. C1 S/W Ver. 2.06
Press the P key on the integrator to power up the lights, the front
switches, and the printer's computer system.
Note: Allow the printer a 5 minute warm-up period before any
calibration procedures. This will allow for complete and accurate
light level stabilization.
Press the integrator I key to select the desired light level to be calibrated,
always start at Low Intensity.
For 6kW
In order to prevent possible damage to the high resolution printers Mylar®
while calibrating we recommend you set the no vacuum feature.
Press the V key on the keypad, the Memory and Exposure windows
will dim.
Press the 9 key three times.
Press the V key once. This will prevent vacuum while calibrating. The
Vacuum window will read [ _ ---] .
The high resolution printer's calibration has been set at the factory.
Upper frame top surface
Upper frame bottom surface
Lower frame top surface
Lower frame bottom surface
Note: Preset all 12 calibration factor numbers to 500 units. Place a
slim UV meter facing up on the center of the top frame, below
the Mylar®.
Enter a 500 unit exposure into the integrator. Be sure the seconds mode
is off.
Press the G button twice. This will send the frame into the unit and
start the exposure.
After the exposure, retrieve your frame by holding down the S button
and press G button. When the frames start to move, release both
buttons.
Record the resulting mj reading from the meter.
Low 2000W
Medium 3500W
High 6000W
3-5

Advertisement

Table of Contents
loading

Related Products for Accuprint AP30CL - 6000

Table of Contents