[ S EL_]
[ b cnt]
[ S EL_]
[ F rCL]
[ S EL_]
4-6
Press 1,2,3t 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in the select mode.
Press the Y key once. The Memory window will read [ S u] .
Press and release the e key until [ b cnt] appears in the Exposure window.
This places you in the board count option.
Press the V key to cycle the board count ON or OFF.
Press the 0 key twice to exit this mode.

Frame Control Interface Mode

The frame control interface works in conjunction with each frame's
magnetic switch. If either frame is open, motorized transport will not
function. This prevents inadvertent frame movement with the outer frame
open. It is recommended that this safety feature be turned ON at all times.
In the event of a switch failure or a unit without switches, it can be
bypassed.
Note: This safety feature will always be ON unless you turn it OFF. To
deactivate the frame control interface mode:
Press the P key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
Press 1,2,3t 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in the select mode.
Press the Y key once. The Memory window will read [ S u] .
Press and release the e key until [ F rCL] appears in the Exposure window.
This places you in the frame control interface mode.
Press the V key to cycle the frame control interface mode ON or OFF.
Press the 0 key twice to exit this mode.

Automatic Vacuum Mode

The automatic vacuum mode allows the printer to start vacuum
automatically by closing the frame. If a preset vacuum delay is used,
such as default vacuum delay, the center display will show the vacuum
countdown. The G button then only needs to be pressed once to start
frame movement. With this feature turned ON, a blank frame cycle will
be initiated simply by pressing the G button once when the frame has
not been opened. To activate this option:
Press the P key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
Press 1,2,3t 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in the select mode.
Press the Y key once. The Memory window will read [ S u] .