Diagnostics; Output Diagnostics; Output Functions Check - Accuprint AP30CL - 6000 Service Manual

Closed loop cooling high resolution printer
Table of Contents

Advertisement

5.

Diagnostics

[ S EL_]
[ o 000]
94MS41 Rev. C1 S/W Ver. 2.06

Output Diagnostics

One of the many advancements OLEC has introduced to the field is the
ability of its equipment to run a self-diagnostic check. All computer-
activated functions and all internal and external switches can be checked
out on the integrator display by using the numerical keypad.

Output Functions Check

Press the P key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
Press 1,2,3, then 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in select mode.
Press the 6 key to enter the Diagnostics mode. The number in the
Vacuum window will be the sum of all values for peripherals that are
turned On.
Press the 9 key to reset the Diagnostics mode. This turns Off all
peripherals. Therefore the Vacuum window will indicate [ o 000] .
Refer to the Functions Table.
Press the number key to actuate the desired function. The numerical value
shown in the table should appear in the Vacuum window.
Press the function key number again to turn off the function. Press the
9 key to turn off all functions.
Press the 0 key twice to return to normal operation.
5-1