5.
Diagnostics
[ S EL_]
[ o 000]
94MS41 Rev. C1 S/W Ver. 2.06
Output Diagnostics
One of the many advancements OLEC has introduced to the field is the
ability of its equipment to run a self-diagnostic check. All computer-
activated functions and all internal and external switches can be checked
out on the integrator display by using the numerical keypad.
Output Functions Check
Press the P key on the integrator to power up the light, the front remote
•
switches, and the exposure unit's computer system.
Press 1,2,3, then 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in select mode.
Press the 6 key to enter the Diagnostics mode. The number in the
•
Vacuum window will be the sum of all values for peripherals that are
turned On.
Press the 9 key to reset the Diagnostics mode. This turns Off all
peripherals. Therefore the Vacuum window will indicate [ o 000] .
•
Refer to the Functions Table.
•
Press the number key to actuate the desired function. The numerical value
shown in the table should appear in the Vacuum window.
•
Press the function key number again to turn off the function. Press the
9 key to turn off all functions.
Press the 0 key twice to return to normal operation.
•
5-1