Accuprint AP30CL - 6000 Service Manual page 40

Closed loop cooling high resolution printer
Table of Contents

Advertisement

[ 0 044]
[ 0 172]
[ 0 060]
[ 0 004]
[ 0 005]
[ 0 012]
5-4
Lower tray in, Frame switch closed, Door and Emergency switches closed.
The Exposure window should read [ 0 044] .
When the G button is pushed the value should change to [ 0 172] .
When the S button is pushed the value should change to [ 0 060] .
Typical values that you will see when a fault occurs.
Indicates neither frame in position, magnetic frame switches closed, and
does not have the correct reading from either the door switches or
emergency z button.
Indicates upper frame in position, magnetic frame switches closed, and
does not have the correct reading from either the door switches or
emergency z button.
Indicates lower frame in position, magnetic frame switches closed, and
does not have the correct reading from either the door switches or
emergency z button.
Whatever the switch value display reads when the G button is pressed
and the value does not increase by a value of 128 the G switch is bad.
Whatever the switch value display reads when the S switch is pressed
and the value does not increase by a value of 16 the S switch is bad.
94MS41 Rev. C1 S/W Ver. 2.06