Electrical Specifications And Connections - Accuprint AP30CL - 6000 Service Manual

Closed loop cooling high resolution printer
Table of Contents

Advertisement

94MS41 Rev. C1 S/W Ver 2.06
Connect the main leads to the 4 position or 6 position terminal block and
connect the ground lead to the single ground terminal (see next page for
hook up).
Reinstall the lower side door.
Energize the main power circuit. You should hear the lamp head and
power supply cooling fans go into a cool-down cycle. Ensure that the
voltage select switch on the hinged control panel is switched to the lit
LED.
Install the lower front and rear black trim pieces over the forklift channels,
5
using a
/
" Allen wrench.
32

Electrical specifications and connections

L1
Figure A
L1
Power Supply #1
Blowers
Vacuum
Pumps
Electronics
Drives
Etc.
Figure B
AP 30CL - 6000 printer input
3 phase (Delta)
See Figure B
3 phase (Wye)
See Figure A
L2
380 / 415V~
OLITE
Power Supply
N
Blowers
Vacuum
Pumps
Electronics
Drives
Etc.
Earth
Ground
L3
L2
208V~
OLITE
208V~
OLITE
Power
Supply #1
Earth
Ground
L3
3 wires + ground
3 wires + neutral + ground
380 / 415V~ 50Hz Connection
Wye: 3 Wires + Neutral + Ground
Terminal Block
L1 L2 L3
N
208/240V~ 50Hz Connection
DELTA: 3 Wires + Ground
Terminal Block
L1 L2 L3
N
208/240V~ 60 Hz, 65 amp.
380/415V~ 50 Hz, 34 amp.
1-3