Adjust The 'Fast' Pot On The Control Box - Accuprint AP30CL - 6000 Service Manual

Closed loop cooling high resolution printer
Table of Contents

Advertisement

[ 0 096]
!
94MS41 Rev. C1 S/W Ver 2.06
Press the 6 key again: upper tray should move in, the Vacuum window
should read [ 0 096] .
Set volt meter for VDC and measure across pins 5 & 6 on motor speed
connector. Adjust the 'SLOW' pot on the control box to read 25 to 32
VDC. Notice that the frame moves slower than normal. The total travel
time of the frame should be 12 seconds.
Exit the diagnostic mode by pressing the 9 key then the 0 key.

Adjust the 'FAST' pot on the control box.

Depress and hold the 'STOP' key then press the 'GO' key and then release
both keys to start a blank frame cycle, no vacuum or exposure.
Measure across pins 5 & 6 on motor speed connector. Adjust the 'FAST'
pot on the control box to read between 70 and 84 VDC. The frame should
travel at high speed for about 4.5 seconds, then shift to a slower speed
and stop about 0.750" to 1" from the end of the tray rod.
C Verify the adjustment by noting the position of the frame when
it is inside the Unit. Check the frame position switches for
each frame. When adjusted properly, the frame will come to
a stop depressing the first switch, but not the second. If the
second switch is depressed, check slow speed adjustment.
SLOW
FAST
MOTOR SPEED
COMMUNICATION
12 VDC
STOP
SLOW
OUT
IN
MOTOR
A/C
ACCESSORY
L - SWT
POWER SUPPLY
HF1 BLOWER
HF1 BLOWER
LINE VOLTAGE
VACUUM
SELECTION
PUMPS
SWITCH
POWER SUPPLY