11-4
Open the left side sliding door on the printer and locate the drive motor
at the left rear corner of the cabinet.
Loosen the two set screws which lock the hex nut to the motor shaft.
Adjust the hex nut until the minimum setting is found that provides frame
movement with no slippage.
Retighten the set screws in the hex nut.
Close the sliding door.

Frame Speed Adjustment

Note: Frame speed is set at the factory and normally does not require
adjustment.
Note: An adjustment of the frame speed must be preformed whenever
the Control Box PCB, part #64CT464, or the Motor Speed Control
Board, part #31MSC02 is replaced. This adjustment is critical,
failure to do so can damage the board and/or hardware.
Locate the 'FAST' and 'SLOW' potentiometers in the upper lefthand corner
of the Control Box. The frame speed adjustments will be made from
these pots.
Activate the Diagnostics Mode through the keypad;
Press the 1, 2, 3 t 4 keys, the center display will read [ S EL_] .
Press the 6 key: this will activate the diagnostic mode.
Press the 9 key: this will reset the Vacuum window to [ 0 000] .
Press the 7 key to set motor drive: the Vacuum window should read
[ 0 064] .
Press the 6 key: upper tray should move in, the Vacuum window should
read [ 0 096] .
Press the 6 key: lower tray should move in, the Vacuum window should
read [ 0 064] .
FAST
SLOW
MOTOR SPEED
COMMUNICATION
12 VDC
SLOW
STOP
IN
OUT
MOTOR
A/C
ACCESSORY
L - SWT
POWER SUPPLY
HF1 BLOWER
HF1 BLOWER
94MS41 Rev. C1 S/W Ver 2.06
LINE VOLTAGE
VACUUM
SELECTION
PUMPS
SWITCH
POWER SUPPLY

Advertisement

Table of Contents
loading

Table of Contents