Regulations, Safety Regulations And Guarantee; Regulations; Safety Regulations - Sames Mach-Jet User Manual

Table of Contents

Advertisement

1. Regulations, Safety Regulations and Guarantee

1.1. Regulations

The "Mach-Jet" spray gun is in conformity with standard EN50050/2001. A file is open with a notified
body to obtain the standard CE test certificate (Compliance with directive 94/9/CE)
Spray gun marking and CRN 457 control module marking :
0080
II 2 D
MACH-JET GUN
P/N 1524463
ISSeP04ATEX119
Meylan France
EEx 2 mJ
When configured
FM
according to # 800000045
APPROVED
For Electro. Fin. Appl. CL. II, Spray Matl.

1.2. Safety Regulations

This equipment may be dangerous if it is not used in compliance with the security regulations specified
in this manual.
• The CRN 457 electro-pneumatic control module must never be installed where there is a risk of
explosion.
• The electrostatic paint spraying equipment must only be used by qualified personnel fully informed
of rules no.° 1 to 12 as follows:
1 A warning notice written in a language understood by the operator, summarising safety regulations
nos.° 2 to ° 9, section 1.1 of this manual, must be placed in a clearly visible position close to the
powder-spraying booth.
2 Shoes intended for operator use must be anti-static and comply with the ISO 2251 publication. If
gloves are used, only anti-static gloves or gloves ensuring grounding of the operator may be worn.
3 The floor in the area in which the operator works must be anti-static (ordinary bare concrete floors
are anti-static).
4 Powder spraying must be carried out in front of a ventilated booth designed for the purpose. Start-
up of the CRN 457 must be interlocked with operation of the ventilation system.
5 Skin-contact with or inhalation of products used with this equipment may be dangerous for
personnel (cf. Safety sheets for products used).
6 All conducting structures such as floors, walls of powder-spraying booths, ceilings, barriers, parts
to be painted, powder distribution tank, etc. that are inside or near the work station and the earth
terminal on the electro-pneumatic control module must be electrically connected to the ground
system protecting the electrical power supply.
7 Parts to be painted must have a resistance in relation to the ground system that is less than or
equal to 1 M Ω .
Index revision : H
5