Error code 6200
Detected that the drum unit was not set by detecting the GRID terminal current.
<User Check>
• Set the drum unit correctly.
Step
Dirt on the GRID terminals of the
1
drum unit and those of the
machine
Dirt on the high-voltage power
2
supply PCB terminal
high-voltage power supply PCB
3
failure
4
Main PCB failure
Electrodes location of the toner cartridge and drum unit
Electrodes location of the machine
Cause
Clean the CHG and GRID terminals of the drum
unit and those of the machine.
(Refer to
Clean the high-voltage power supply PCB
terminal.
Replace the high-voltage power supply PCB
ASSY.
Replace the main PCB ASSY.
Fig. 2-8
Fig. 2-9
2-48
Remedy
Fig. 2-8
and
Fig.
2-9.)
Side surface of
drum unit
Bottom surface of
drum unit
Confidential