Fujitsu AUYG07LVLA Design & Technical Manual page 56

Hide thumbs Also See for AUYG07LVLA:
Table of Contents

Advertisement

6-2-5.
FLOOR TYPE
MODEL : AG G09LVCA
Outdoor Temperature
(°CDB)
(°CWB)
-15.0
-16.0
-10.0
-11.0
-5.0
-7.0
0.0
-2.0
5.0
3.0
7.0
6.0
8.0
10.0
15.0
10.0
20.0
15.0
MODEL : AG G12LVCA
Outdoor Temperature
(°CDB)
(°CWB)
-15.0
-16.0
-10.0
-11.0
-5.0
-7.0
0.0
-2.0
5.0
3.0
7.0
6.0
10.0
8.0
10.0
15.0
20.0
15.0
MODEL : AG G14LVCA
Outdoor Temperature
(°CDB)
(°CWB)
-15.0
-16.0
-10.0
-11.0
-5.0
-7.0
0.0
-2.0
5.0
3.0
7.0
6.0
10.0
8.0
15.0
10.0
20.0
15.0
TC : Total Capacity kW.
The data is based on the following conditions.
Pipe length : 5m [Outdoor unit - Branch box], 3m [Branch box - Indoor unit]
Height difference : 0m [Outdoor unit - Indoor unit].
Indoor temperature (°CDB)
16.0
18.0
20.0
24.0
TC
TC
TC
2.36
2.18
2.00
1.83
2.64
2.44
2.24
2.05
2.94
2.71
2.49
2.28
3.21
2.96
2.72
2.49
3.44
3.18
2.92
2.67
3.52
3.25
2.99
2.73
3.52
3.25
2.99
2.73
3.52
3.25
2.99
2.73
3.52
3.25
2.99
2.73
Indoor temperature (°CDB)
16.0
18.0
20.0
24.0
TC
TC
TC
3.13
2.88
2.65
2.42
3.50
3.23
2.97
2.71
3.89
3.59
3.30
3.02
4.25
3.92
3.61
3.29
4.56
4.21
3.87
3.53
4.66
4.30
3.96
3.62
4.66
4.30
3.96
3.62
4.66
4.30
3.96
3.62
4.66
4.30
3.96
3.62
Indoor temperature (°CDB)
16.0
18.0
20.0
24.0
TC
TC
TC
3.79
3.50
3.22
2.94
4.24
3.91
3.60
3.29
4.72
4.35
4.00
3.65
5.15
4.75
4.37
3.99
5.52
5.10
4.69
4.28
5.65
5.22
4.80
4.38
5.65
5.22
4.80
4.38
5.65
5.22
4.80
4.38
5.65
5.22
4.80
4.38
- (02 - 37) -
HEATING CAPACITY
26.0
TC
TC
1.59
1.78
1.98
2.17
2.32
2.38
2.38
2.38
2.38
26.0
TC
TC
2.11
2.36
2.63
2.87
3.08
3.15
3.15
3.15
3.15
26.0
TC
TC
2.56
2.86
3.18
3.48
3.73
3.82
3.82
3.82
3.82
2. MODEL SELECTION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents