CAPACITY CHANGE RATE BY BRANCH PIPING LENGTH
Change rate in capacity
Refrigerant piping connection diameter: Liquid ø6.35mm, Gas ø9.52mm
Indoor unit model code: 07 / 09 / 12
Branch piping
m
length
Change rate in
%
cooling capacity
Change rate in
%
heating capacity
Refrigerant piping connection diameter: Liquid ø6.35mm, Gas ø12.70mm
Indoor unit model code: 14 / 18
Branch piping
m
length
Change rate in
%
cooling capacity
Change rate in
%
heating capacity
Refrigerant piping connection diameter: Liquid ø6.35mm, Gas ø15.88mm
Indoor unit model code: 24
Branch piping
m
length
Change rate in
%
cooling capacity
Change rate in
%
heating capacity
3
5
10
15
100
98.3
94.2
90.0
100
98.9
96.2
93.5
3
5
10
15
100
99.2
97.1
95.0
100
99.5
98.3
97.0
3
5
10
15
100
99.6
98.5
97.5
100
99.9
99.5
99.0
- (02 - 16) -
100
95
90
0
5
10
Branch piping length
100
95
90
0
5
10
Branch piping length
100
95
90
0
5
10
Branch piping length
2. MODEL SELECTION
Heating
Cooling
15 (m)
Heating
Cooling
15 (m)
Heating
Cooling
15 (m)