MODEL : AU G18LVLA, AU G18LVLB
Outdoor Temperature
(°CDB)
(°CWB)
-15.0
-16.0
-10.0
-11.0
-5.0
-7.0
0.0
-2.0
5.0
3.0
7.0
6.0
8.0
10.0
15.0
10.0
20.0
15.0
TC : Total Capacity kW.
The data is based on the following conditions.
Pipe length : 5m [Outdoor unit - Branch box], 3m [Branch box - Indoor unit]
Height difference : 0m [Outdoor unit - Indoor unit].
Indoor temperature (°CDB)
16.0
18.0
20.0
24.0
TC
TC
TC
4.63
4.27
3.93
3.58
5.18
4.78
4.40
4.01
5.76
5.31
4.89
4.46
6.29
5.80
5.34
4.87
6.74
6.22
5.73
5.23
6.90
6.37
5.86
5.35
6.90
6.37
5.86
5.35
6.90
6.37
5.86
5.35
6.90
6.37
5.86
5.35
- (02 - 29) -
HEATING CAPACITY
26.0
TC
TC
3.12
3.49
3.89
4.24
4.55
4.66
4.66
4.66
4.66