Fujitsu AUYG07LVLA Design & Technical Manual page 252

Hide thumbs Also See for AUYG07LVLA:
Table of Contents

Advertisement

Example 3 (OK)
Outdoor unit
Indoor unit 1
Model
Outdoor unit
AO45
Indoor unit 1
AR18
Indoor unit 2
AR12
Indoor unit 3
AR09
Indoor unit 4
AR09
Indoor unit 5
AR09
Branch box 1
UTP-PY03A
Branch box 2
UTP-PY02A
Example 4 (OK)
Outdoor unit
Indoor unit 1
Indoor unit 2
Model
Outdoor unit
AO48
Indoor unit 1
AS07
Indoor unit 2
AS07
Indoor unit 3
AS07
Indoor unit 4
AS07
Indoor unit 5
AS07
Indoor unit 6
AS07
Indoor unit 7
AS07
Indoor unit 8
AS07
Branch box 1
UTP-PY03A
Branch box 2
UTP-PY03A
Branch box 3
UTP-PY02A
Branch box 1
(3 branches type)
Indoor unit 3
Indoor unit 2
Rated
Total
capacity
capacity
of cooling
(kW)
(kW)
14.0
14.0
5.27
3.52
2.64
16.71
2.64
2.64
-
-
-
-
Branch box 1
(3 branches type)
Indoor unit 3
Indoor unit 4
Rated
Total
capacity
capacity
of cooling
(kW)
(kW)
14.0
14.0
2.05
2.05
2.05
2.05
2.05
16.4
2.05
2.05
2.05
-
-
-
-
-
-
Branch box 2
(2 branches type)
Indoor unit 4
Indoor unit 5
Connectable indoor
unit capacity (kW)
Min.
Max.
 80%
 130%
11.2
18.2
-
-
-
-
Branch box 2
(3 branches type)
Indoor unit 5
Indoor unit 6
Connectable indoor
unit capacity (kW)
Min.
Max.
 80%
 130%
11.2
18.2
-
-
-
-
-
-
- (06 - 04) -
Capacity ratio
119%
Judgement
.
.
.
-
-
Branch box 3
(2 branches type)
Indoor unit 7
Indoor unit 8
Capacity ratio
117%
Judgement
.
.
.
-
-
-