2.4.5.2 DC PSU
2.4.5.3 Protection
The PSU modules have internal protection to avoid damage to the PSU module and the
system. Protection is implemented in two stages: first, a warning is triggered which is
signalled via the PSU LEDs (see below) as well as to Advanced Platform management.
Once a critical threshold has been crossed, the 2
main power output of the module, also signalled via PSU LEDs as well as to platform
management.
Table 2-25: PSU Protection Warning and Critical Levels
Item
Overvoltage: 12V main
Overvoltage: 12V Standby
Over Current / Short Current
PSU Inlet temperature
Component temperature
FAN
After a shut down, the PSU module can be restarted via a cycle of the primary power or
by Advanced Platform Management.
SKY-8100 Manual V05 20161229
Figure 2-31: DC PSU LED Indications
Warning
--
--
--
70°C
95°C
2000RPM
Copyright 2016 Advantech Co. Ltd. All rights reserved.
nd
stage protection will shut down the
Critical
13.3V ... 14.5V
13.3V ... 14.5V
120%...150%
75°C
100°C
1500RPM
Page 66