Meiko UPster U 400 Operating Instructions Manual page 28

Glass and dishwashing machine
Table of Contents

Advertisement

Operating Instructions UPster U 400 / U 500 / U 500S
17.3.1 View/modify parameters
9735077
Display
Press the "Accept" button to confirm.
Now, the first parameter is displayed with a value.
Press the "I" key to go forwards and the "II" key to go backwards, until the parameter you
require is displayed.
Confirm the parameter to be modified by pressing the "accept" key, the value will flash.
Increase the value using the "I" key or reduce it using the "II" key and confirm with the
"Accept" key.
You can leave this level by pressing the "0" key.
See 17.4 for list of parameters.
17.3.2 Ventilating the rinse aid inlet
Press the "Accept" button to confirm.
This actuates dosing pump; the remaining running time is indicated.
You can leave this level by pressing the "0" key. Ventilation is cancelled.
17.3.3 Ventilating the detergent inlet
Press the "Accept" button to confirm.
This actuates dosing pump; the remaining running time is indicated.
You can leave this level by pressing the "0" key. Ventilation is cancelled.
Should the ventilation process be insufficient, repeat the process.
The function "vent detergent pipe" is not existing with machines including detergent
dosing system type ADT ('Advanced Dosing Technology with depression dosing). The
detergent dosing pipe is vented automatically when the first cycle is running, after filling
of the detergent reserve container.
Design and construction subject to change without prior notice