Maintenance and care

10.1 Care, general

The appliance has been designed to minimise the need for cleaning, care and mainte-
nance.
However, for reliable, safe and long-term function of the machine, and in the interest
of hygiene and cleanliness, correct care and maintenance is necessary.

10.2 Refill detergent

There are two different types of detergent containers:
Incorporated container
The storage container is translucent white in colour and is located in the lower part of the
stationary warewashing machine. The lid can be opened after the container has been re-
moved from its position.
 Re-fill the container marked "detergent" if necessary.
External storage container
The container is located in the immediate vicinity of the machine.
 Check the filling level of the container and if necessary, replace it with a full one.
Only non-foaming alkali detergents (pH > 7) suitable for commercial glass and dish-
washing machine may be used.
Detergent dosing units must be checked to see if they are functioning properly if
there is reason to believe that they are malfunctioning. Visual inspection!

10.3 Refilling with rinse aid

There are two different types of rinse aid containers:
Incorporated container
The storage container is translucent blue in colour and is located in the lower part of the
stationary warewashing machine. The lid can be opened after the container has been re-
moved from its position.
 Re-fill the container marked "rinse-aid" if necessary.
External storage container
The container is located in the immediate vicinity of the machine.
 Check the level and, if necessary, replace the container by a full one.
Only non-foaming acid rinse aid (pH < 7) suitable for commercial glass and dishwashing
machine may be used.
If you suspect a malfunction, check the final rinse dosing unit. Visual inspection!