Install U Bracket Mount

Before installation begins, verify you have the applicable vehicle mounting bracket assembly components necessary, as shown
CAUTION - This device is intended to transmit RF energy. For protection against RF exposure to humans and in accor-
dance with FCC rules and Industry Canada rules, this transmitter should be installed such that a minimum separation dis-
tance of at least 20 cm (7.8 in.) is maintained between the antenna and the general population. This device is not to be
co-located with other transmitters.
in the following figures.

Components - U Bracket Mounting Assembly

The U bracket kit is available in two configurations:
• With a U Bracket included for new vehicle installations
• Without a U Bracket for installing the Thor VM1 in place of a previous Honeywell vehicle mounted computer, such as a
VX6 or VX7.
U Bracket (only included in kits for new installations)
Adapter Bracket (includes screws, flat washers and lock washers to attach
Adapter Bracket to Thor VM1 and to attach Adapter Bracket to existing
U Bracket (for example, to a vehicle where a VX1, VX2, VX4, VX5, VX6 or
VX7 was previously installed)

Procedure - U Bracket Assembly

Equipment Needed: Sockets and a Torque wrench capable of measuring to 50 inch pounds (5.64±.56 N/m).
Note: Torquing tool is not supplied by Honeywell.

Torque Measurement

You will need a torquing tool capable of torquing to 35-50 inch pounds (1.10 N/m). Torque all screws and bolts accord-
ing to the following table:
For these bolts...
1/4-20x5/8 Bolts
M5x16mm Bolts
1/4 Bolts (user supplied)
4 - 10
Torque to
50 in/lb (5.6 N/m)
35 in/lb (4.0 N/m)
50.0±5 in/lb (5.64±.56 N/m)