Manual Control Wiring Diagram
Ignition wire must be left unconnected and Enable Auto-On must not be selected on the Misc tab of the
Options
(page 5-78) control panel.
Existing Circuitry On Vehicle
Battery
Main Switch
+Vo
-Vo
Fuse - See
Warning
statement below
See Caution statement below
CAUTION
For battery powered vehicles:
• Red wire is connected to battery positive. If there is a red wire and a red/white wire, twist them
together and connect to battery positive.
• Black wire must be connected to battery negative. If there is a black wire and a black/white wire, twist
them together and connect to battery negative.
• Green wire must be connected to the vehicle chassis ground.
For internal combustion engine powered vehicles:
• Red wire is connected to battery positive. If there is a red wire and a red/white wire, twist them
together and connect to battery positive.
• Black wire is connected to battery negative. If there is a black wire and a black/white wire, twist them
together and connect to battery negative.
• Green wire is connected to the vehicle chassis ground, which can also be battery negative.
WARNING
For proper and safe installation, the input power cable must be connected to a fused circuit on the ve-
hicle. If the supply connection is made directly to the battery, the fuse should be installed in the positive
lead within 5 inches of the battery's positive (+) terminal. The fused circuit requires a maximum time
delay (slow blow) fuse with a current rating as noted below.
• For 12VDC input, use a 10A slow blow fuse that has a DC voltage rating greater than 12VDC.
• For 24VDC input, use a 6A slow blow fuse that has a DC voltage rating greater than 24VDC.
• For 36VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 36VDC.
• For 48VDC input, use a 3A slow blow fuse that has a DC voltage rating greater than 48VDC.
Note: For North America, a UL Listed fuse is to be used.
Cable for optional
screen blanking
connection
Red/White (if present)
Red
Black/White (if present)
Black
Green
Blue
(not connected)