Section 15. SYSTEM OPERATION

This section provides the following information:

• User codes

• Keypad functions
• Emergency keys
User Codes
* User codes are required only if a keypad is installed on the control.
This system provides 1 Master code and 5 secondary codes (Users 2-6). These
are described below.
Master Code
The installer programs the 4-digit Master Code initially as part of the
programming procedure. The factory default Master code is "5-1-1-0 ", but may
be changed in field
The Master code is the only code that can allow re-entry into programming
mode and also, in normal operation mode, is used to enter the 4-digit code for
the main user (user #2), which allows access to the normal functions of the sys-
tem (The main user {#2} may also enter additional users, 3-6).
See MECHANICS OF PROGRAMMING for information on exiting the
programming mode via fields *98 or *99.
User Codes
In normal operation mode, the Master (installer's) code (and user code #2)
may be used to assign up to 5 additional 4-digit user codes. It can also be used
to remove secondary codes from the system (individually).
To assign (or change) a Secondary user code, enter (via keypad):
Master Code + [CODE key] + User # (2–6) + desired
Secondary Code (4-digits)
The system will emit a single beep when each secondary code has been suc-
cessfully entered.
To delete a Secondary user code, enter (via keypad):
Master Code + [CODE key] + User # (2–6)
Notes: • All Master and Secondary user codes permit access to the system for
silencing and resetting alarms.
• The Master code may assign user codes 2-6; User 2 may assign user codes 3-
6
• The Master code may bypass ALL zones while users 2-6 may bypass 24 hour
non-fire zones only.
• The Master code may initiate both the Walk Test and Fire Drill; User 2 may
initiate the Fire Drill only; Users 3-6 may NOT initiate any of the test
modes.
• If a secondary code is inadvertently repeated for different users, the lower
user number will take priority.
USER #
1 (MASTER)
2 (MAIN USER) NO
3 - 6
20.
*
USER CODE FUNCTION SUMMARY TABLE
ENTER
SILENCE
PROGRAM
ALM, SUP,
MODE
& TRBL
YES
YES
YES
NO
YES
–58–
ADD /
CHANGE
BYPASS
USERS
ZONES
1 - 6
ALL
2 - 6
24 HR.
NO
24 HR.
ENTER
TEST
MODES
WALK TEST,
FIRE DRILL
FIRE DRILL
NONE