This will be sent when the supervisory condition is restored.
Press *60 TROUBLE REPORT CODE
This will be sent if a zone goes into trouble.
Press *61 BYPASS REPORT CODE
This will be sent when a zone is manually bypassed.
Press *62 AC LOSS REPORT CODE
Timing of this report is random within 6-12 hours after AC is lost.
If AC restores before the report goes out, there is no AC loss report.
Press
63
LOW BAT REPORT CODE
*
This will be sent when a low battery condition exists in the
system's standby battery.
Press
64
NORMAL TEST REPORT CODE
*
This is sent periodically (* provided no trouble or supervisory
conditions exist; otherwise an Off-Normal Test code - as
programmed in *84 - will be reported) to test that the control and
phone lines are operational (frequency of report is selected in field
*49).
Press
69 GROUP RESTORES FOR TROUBLE and BYPASS
*
Enter 0 if a report is desired for each zone restoral, as it occurs.
This is the default. Enter 1 if a report is not desired until all
zones have restored.
Note: "1" not applicable to Contact ID reporting.
Press
*
70 ALARM RESTORE REPORT CODE, 1st DIGIT
This is sent when the zone that caused an alarm is restored to its
non-faulted condition. 2nd digit is automatically sent as the 2nd
digit of the zone alarm report code programmed in field
expanded or 4+2 reporting is selected.
Press
71 TROUBLE RESTORE REPORT CODE
*
This is sent when a trouble in a zone is restored. Field *69 applies.
Press
72 BYPASS RESTORE REPORT CODE
*
This is sent when a zone that has been bypassed is un-bypassed.
Field *69 applies.
Press
73 AC RESTORE REPORT CODE
*
This is sent when AC power has been restored after an AC power
outage.
Press
74 LOW BAT RESTORE REPORT CODE
*
This is sent when a system low battery condition is restored to
normal.
Press *79 MAIN/BACKUP DIALER ENABLE
Enter [1] to enable or [0] to disable each dialer
(default = [1][1])
Press *84 MISCELLANEOUS REPORT CODES
Press * 94 DOWNLOAD PHONE NUMBER
| | | | | | | | | | |
0–9, # +11 for "[*]", # + 12 for "#", # + 13 for a pause. Do not fill unused
spaces. End field by entering "
–45–
|
FIRE W/T FIRE W/T
START
Enter up to 12 digits;
". To clear entries, press
*
|
|
|
|
|
*56
, if
|
|
|
|
|
M B
|
|
OFF-
END
NORM
TEST
.
*94*