Section 18. Specifications & Accessories; Specifications - ADEMCO 5110XM Installation Instructions Manual

Microprocessor-based fire alarm control/communicator
Hide thumbs Also See for 5110XM:
Table of Contents

Advertisement

Section 18. SPECIFICATIONS & ACCESSORIES
Specifications ––––––––––––––––––––––––––––––––––––––––––––––––––––
CONTROL
1. Physical:
12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x 76mm)
2. Electrical:
VOLTAGE INPUT: from built-in transformer supplying 18VAC at 40VA
to 5110XM. Transformer requires nominal 120VAC, 600mA input.
RECHARGEABLE BACK-UP BATTERY: 12VDC, 7AH min., 14AH, max.
(Gel type).
Charging Voltage: 13.7VDC, nominal
BELL OUTPUT: 12VDC, 1.0A output. Selectable for style Y EOLR
supervision (using 610-7 EOLR) or no supervision.
AUXILIARY POWER OUTPUT: 12VDC, 350mA max.
AUXILIARY RELAY OUTPUT: Selectable for wet form C output rated at
12VDC, 350mA standby max/1A alarm max or dry form C output with
contacts rated at 30VAC/VDC, 2A max, resistive loads.
TOTAL OUTPUT POWER: combined aux power and aux relay power
standby currents cannot exceed 350mA. Combined aux power, aux relay
power and bell alarm currents cannot exceed 1A.
STANDBY TIME: (see Table in Final Powerup section)
FUSING: PTC circuit protectors on battery input and on aux. power,
aux. relay, and bell outputs.
3. Communication:
FORMATS SUPPORTED:
Ademco 4+2 Express (DTMF, 10 characters per second)
Ademco Contact ID Reporting (DTMF, 10 characters per second)
Ademco Low Speed 3+1, 4+1, 4+2 (10 pulses per second)
Radionics/SESCOA 3+1, 4+1, 4+2 (20 pulses per second)
Line Seize: Double Pole
TLM Threshold: Good line when Tip-Ring voltage exceeds 2V; Bad line
when less than 2V
Ringer Equivalence: 0.7B
FCC Registration No.: AC398U-68192-Al-E
4. Maximum Zone Resistance:
Zones 1–4 = 300 ohms excluding EOLR ;Zone 5 = 100 ohms excluding
EOLR
5. Built-in Indicators:
Seven LEDs: AC Power, Comm Fail, Line Fault, Silence Audible, Main
Dialer Line Seize, Backup Dialer Line Seize
Warning Buzzer: Piezo-electric buzzer sounds for Alarm, Trouble and
Supervisory conditions. Silenced by pressing the Silence/Reset button (or
by code+off on keypad, if used).
6. Remote Keypads:
Supports up to four 6137(gray)/6137R(red) fixed word and
6139(gray)/6137R(red) alpha keypads depending on system usage and
current loading. When used as a slave DACT, keypads are optional, but
may be used for supplemental DACT status annunciation. When used as a
stand-alone control, one keypad, mounted within 3 feet of the control, with
the wiring run in conduit, must be used .