Programming Communication Options

Fields
40,
41,
42:
*
*
*
Enter up to the number of
digits shown. Do not fill
unused spaces.
Enter 0–9,
# + 11 for '
* '
# + 12 for '#'
# + 13 for a pause
(2.5 secs)
To program communications options, do the following:
1. With at least one alpha keypad (6139 or 6139R) connected to the
system, power up the system. If necessary, refer to the Final Power-
Up section for the power-up procedure.
2. Enter the programming mode by keying the following on the alpha
keypad: Master code (5 1 1 0) + 8 0
Press *33
BACKUP DIALER PULSE/TONE
Enter 0 for pulse dial, 1 for tone dial. Default =0
Press
40
PABX ACCESS CODE
*
Enter up to 4 digits if PABX is needed to access an outside line. If
fewer than 4 digits are needed to be entered, exit by pressing *
and next field number (e.g., 41). To clear entries from field, press
*40*.
Press
41
PRIMARY PHONE No
*
| | | | | | | | | | |
Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing
number (e.g., 42). To clear entries from field, press
Press
42
SECONDARY PHONE No
*
| | | | | | | | | | |
Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing
number (e.g., 43). To clear entries from field, press
Press
*
43 SUBSCRIBER ACCOUNT No
(Enter 3 or 4 digits).
Enter digits 0–9; #+11 = B; # +12 = C; # +13 = D; #+14 = E; or #
+15 = F.
To clear entries from field, press
See blank programming form for examples of account no. entries.
If only 3-digits are needed exit by pressing * after the 3rd digit
plus the next field number (e.g., 45).
Press
45 MAIN DIALER PULSE/TONE
*
Enter [1] for Touch Tone or [0] for Pulse Dial (default = 0)
Press
46 REPORT FORMAT
*
(* applies to BOTH primary and secondary numbers)
Determines which format is to be used to report to the central
station.
0 = 3+1; 4+1 ADEMCO Low Speed Standard (this is the default)
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Low Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting (* Recommended)
8 = 3+1; 4+1 ADEMCO Low Speed Expanded
9 = 3+1; 4+1 Radionics Expanded