9. INITIALIZATION OF THE SETTING DATA

All contents of function setting of SC-922 can be returned to the standard set values.
(Caution) Do not turn OFF the power on the way of initializing operation. Program of the main unit may be
broken.
4) Turn OFF the power switch and turn ON the power switch after closing the front cover. The machine returns to
the normal motion.
(Caution) 1. When you carry out the aforementioned operation, the neutral position correction value for
the pedal sensor is also initialized. It is therefore necessary to carry out automatic correction
of the pedal sensor neutral position before using the sewing machine. (Refer "Instruction
Manual Automatic compensation of neutral point of the pedal sensor")
2. When you carry out the aforementioned operation, the machine-head adjustment values are
also initialized. It is therefore necessary to carry out adjustment of the machine head before
using the sewing machine. (Refer "5.-(7) Adjusting the machine head")
3. Even when this operation is performed, the sewing data set by the operation panel cannot be
initialized.
B
1) Turn ON the POWER switch with all of switch
pressed.
2) "rS" is displayed on indicator
initialization.
3) The buzzer sounds after approximately one
second (single sound three times, "peep", "peep",
and "peep"), and the setting data returns to the
standard setting value.
– 49 –
, switch
and
B
switch
held
with a blip to start