JUKI SC-922 Engineer's Manual page 32

Hide thumbs Also See for SC-922:
Table of Contents

Advertisement

(Start level ; U : User's mode, S : Service mode)
No.
Item
141
Setting of
Selection of accessory devices is performed.
accessory
devices
142
Setting of
Setting of the simplified program is performed.
simplified
program
143
Brake start angle The reserve brake start angle after thread trimming
when the thread
is specified.
trimming stop at
the upper position
144
Setting of
The alternate vertical output is automatically
stitches count
canceled by the predetermined stitching count.
for canceling
0 : Disabled
alternate
1 to 30 stitches
vertical output
145
Alternate
The delay time from turning on the alternate vertical
vertical
switch to output start is specified
output delay
0 : Disabled
time
10 to 500 (ms)
146
Selection of
The alternate vertical ON/OFF output is forcibly
alternate
provided after thread trimming.
vertical output
0: Retention of output state
after thread
1 : OFF output
trimming
2 : ON output
147
Alternate
The alternate vertical output at power on can be set
vertical initial
to ON or OFF.
output
0 : Resumes the state when the power was turned
1 : Output OFF
2 : Output ON
148
2-pitch output
The alternate vertical ON/OFF output is forcibly
during reverse
provided after thread trimming.
feed stitching
0 : Retention of output state
at sewing start
1 : OFF output
or end
2 : ON output
149
2-pitch inverted The 2-pitch inverted output in synchronism with the
output during
alternate vertical output can be set to present or
alternate
absent.
vertical output
0 : Function disabled
1 : Function enabled
150
2-pitch initial
The 2-pitch output at power on can be set to ON or
output
OFF.
0 : Resumes the state when the power was turned
1 : Output OFF
2 : Output ON
151
Tie stitch
Stitching temporarily stops at start, end, and each
adjustment
corner of overlapping stitching.
function
0 : Function disabled
1 : Function enabled
152
Temporary stop No. 151 : Temporary stop time is specified when the
time for tie
tie stitch adjustment function is active.
stitch
adjustment
153
Temporary stop The brake angle for temporary stop is specified
brake angle for
when the tie stitch adjustment function is active.
tie stitch
(0: angle of starting down position detection)
adjustment
Do not change the set values with asterisk (
of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
Description
off the last time
off the last time
) mark as they are functions for maintenance. If the standard set value set at the time
Setting range Setting level
0 to 10
(°)
0 to 30
(Stitches)
0 to 500
(ms)
0 to 2
0 to 2
0 to 2
0/1
0 to 2
0/1
0 to 100
0 (ms)
o to 180
(°)
– 28 –
Indication of
function setting
S
1
4
1
F
U
n
S
1
4
2
P
r
o
S
1
4
3
U
1
4
4
S
1
4
5
1
U
1
4
6
U
1
4
7
U
1
4
8
U
1
4
9
U
1
5
0
U
1
5
1
S
1
5
2
S
1
5
3
Ref.
page
40
41
41
0
41
0
41
0
41
0
41
0
41
0
41
0
41
0
42
0
42
0
42
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents